Tankless Water Heater Size Calculator: GPM, Temperature Rise, BTU/h or kW
Two showers at 2.0 GPM and a kitchen faucet at 2.2 GPM running together need 6.2 GPM. Heating that from 50°F groundwater to 120°F is a 70°F rise, which takes 217,200 BTU/h into the water: a gas tankless unit with 228,600 BTU/h gas input at a typical 95% condensing efficiency, or about 63.6 kW for an electric one. Change the fixtures, the temperatures or the efficiency to match your home. This is sizing guidance from a heat-balance formula; the unit’s data sheet shows the flow it delivers at your rise.
Figures based on the sources listed belowUpdated How we calculate
228,600 BTU/h gas input.
228,600 BTU/h gas input
- Method: tankless, gas
- Flow needed: 6.2 GPM (Showers 2 × 2, Kitchen faucets 1 × 2.2)
- Temperature rise: 70°F (120°F outlet − 50°F incoming)
- Heat into the water: 217,200 BTU/h (500.4 × 6.2 GPM × 70°F)
- Gas unit input: 228,600 BTU/h (output ÷ 0.95 efficiency)
- Electric unit power: 63.6 kW (output ÷ 3,412.14), about 265 A at 240 V
- Most flow from your unit: enter a unit size to see the most flow it gives at this rise
Shopping list
- Tankless water heater isolation valve kit
- Tankless water heater descaling pump
- Braided water heater connectors
- Pipe insulation foam
- Plumbing thermometer
Your project
- Showers running at the same time: 2
- Showerhead flow: 2.0 GPM (typical, EPA WaterSense maximum)
- Bathroom faucets running at the same time: 0
- Kitchen faucets running at the same time: 1
- Dishwashers running at the same time: 0
- Clothes washers running at the same time: 0
- Hot water temperature you want: 120 °F
- Incoming groundwater temperature: 50 °F
- Tankless fuel: Natural gas or propane (BTU/h)
- Gas unit efficiency (UEF or thermal efficiency): 95 %
- Gas unit input you are considering (optional): 0 BTU/h
Also pick up
- Tankless water heater isolation valve kit
- Tankless water heater descaling pump
- Braided water heater connectors
- Pipe insulation foam
- Plumbing thermometer
Reopen this calculation: /calculators/tankless-water-heater-size/?s=eyJyb29tIjp7Imxlbmd0aEZ0IjowLCJ3aWR0aEZ0IjowfSwiZGVkdWN0aW9ucyI6W10sIndhc3RlUGN0IjowLjEsInBhcmFtcyI6eyJzaG93ZXJzIjoyLCJzaG93ZXJHcG0iOjIsImJhdGhGYXVjZXRzIjowLCJraXRjaGVuRmF1Y2V0cyI6MSwiZGlzaHdhc2hlcnMiOjAsIndhc2hlcnMiOjAsIm91dGxldEYiOjEyMCwiaW5sZXRGIjo1MCwiZnVlbCI6MCwiZWZmaWNpZW5jeVBjdCI6OTUsInVuaXRCdHUiOjAsInVuaXRLdyI6MH19
Saved projects
No saved projects yet.
Fixture flow rates used in this calculator
| Fixture | Published flow | Source | In this calculator |
|---|---|---|---|
| Showerhead, WaterSense | 2.0 GPM or less | EPA WaterSense | option: 2.0 GPM (typical) |
| Showerhead, federal maximum | 2.5 GPM at 80 psi | US federal standard, 10 CFR 430.32(p) | option: 2.5 GPM |
| Bathroom faucet, WaterSense | 1.5 GPM or less | EPA WaterSense (federal standard 2.2 GPM) | used: 1.5 GPM |
| Kitchen faucet, federal maximum | 2.2 GPM at 60 psi | US federal standard, 10 CFR 430.32(o) | used: 2.2 GPM |
| Dishwasher | 1.0 to 3.0 GPM fill rate | ASHRAE fill rates, as listed by the Building America Solution Center | typical, used: 1.5 GPM |
| Clothes washer | 1.0 to 6.0 GPM fill rate | ASHRAE fill rates, as listed by the Building America Solution Center | typical, used: 2 GPM |
Gas input and electric power by flow and temperature rise
| Flow | 40°F rise | 50°F rise | 60°F rise | 70°F rise | 80°F rise |
|---|---|---|---|---|---|
| 2 GPM | 42,100 / 11.7 | 52,700 / 14.7 | 63,200 / 17.6 | 73,700 / 20.5 | 84,300 / 23.5 |
| 3 GPM | 63,200 / 17.6 | 79,000 / 22 | 94,800 / 26.4 | 110,600 / 30.8 | 126,400 / 35.2 |
| 4 GPM | 84,300 / 23.5 | 105,300 / 29.3 | 126,400 / 35.2 | 147,500 / 41.1 | 168,600 / 46.9 |
| 5 GPM | 105,300 / 29.3 | 131,700 / 36.7 | 158,000 / 44 | 184,400 / 51.3 | 210,700 / 58.7 |
| 6 GPM | 126,400 / 35.2 | 158,000 / 44 | 189,600 / 52.8 | 221,200 / 61.6 | 252,800 / 70.4 |
| 8 GPM | 168,600 / 46.9 | 210,700 / 58.7 | 252,800 / 70.4 | 295,000 / 82.1 | 337,100 / 93.9 |
Temperature rise by incoming water temperature
| Incoming water | Temperature rise | Heat into water (BTU/h) | Gas input (BTU/h) | Electric (kW) |
|---|---|---|---|---|
| 35°F | 85°F | 263,700 | 277,600 | 77.3 |
| 40°F | 80°F | 248,200 | 261,300 | 72.7 |
| 45°F | 75°F | 232,700 | 244,900 | 68.2 |
| 50°F | 70°F | 217,200 | 228,600 | 63.6 |
| 55°F | 65°F | 201,700 | 212,300 | 59.1 |
| 60°F | 60°F | 186,100 | 195,900 | 54.6 |
| 70°F | 50°F | 155,100 | 163,300 | 45.5 |
Most flow from example unit sizes at each temperature rise
| Unit size | 40°F rise | 50°F rise | 60°F rise | 70°F rise |
|---|---|---|---|---|
| Gas, 150,000 BTU/h input | 7.12 GPM | 5.7 GPM | 4.75 GPM | 4.07 GPM |
| Gas, 199,000 BTU/h input | 9.44 GPM | 7.56 GPM | 6.3 GPM | 5.4 GPM |
| Electric, 18 kW | 3.07 GPM | 2.45 GPM | 2.05 GPM | 1.75 GPM |
| Electric, 27 kW | 4.6 GPM | 3.68 GPM | 3.07 GPM | 2.63 GPM |
| Electric, 36 kW | 6.14 GPM | 4.91 GPM | 4.09 GPM | 3.51 GPM |
Methodology & assumptions
A tankless (demand-type) water heater has no tank of stored hot water, so it is sized by two numbers: how much hot water you want at once (the flow in gallons per minute, GPM) and how far it has to heat the water (the temperature rise, in °F). 1) Flow = the fixtures that run at the same time, each at its flow: a showerhead at the flow you pick (1.5, 2.0 or 2.5 GPM), a bathroom faucet at 1.5 GPM, a kitchen faucet at 2.2 GPM, a dishwasher at 1.5 GPM and a clothes washer at 2 GPM. 2) Temperature rise = the hot water temperature you want minus the incoming groundwater temperature. 3) Heat into the water: water weighs 8.34 lb per gallon and one BTU raises a pound of water one °F, so 1 GPM is 60 gal/h × 8.34 lb/gal = 500.4 lb/h, and BTU/h = 500.4 × GPM × rise. 4) Gas: the burner input is the output divided by the efficiency (UEF or thermal efficiency): BTU/h input = output ÷ efficiency. The defaults are 95% for a condensing unit and 82% for a non-condensing one; these are typical estimates, not data-sheet values, so enter the rating of the unit you are considering. 5) Electric: resistance heating turns nearly all the power into heat, so it is taken as 100% efficient and kW = output ÷ 3,412.14 (BTU per kWh). 6) Most flow from a unit you choose: for gas, (input × efficiency) ÷ (500.4 × rise); for electric, (kW × 3,412.14) ÷ (500.4 × rise). Which flows are counted. Only count fixtures that really run together at your busiest moment: a household rarely runs every shower, the dishwasher and the washer at once, and sizing for everything at once buys a much bigger and more costly unit. The faucet, dishwasher and washer flows are the hot-water share of a typical flow, not a measured figure; a shower mixes cold water into the hot, so the hot flow is less than the showerhead’s rating and the result is on the safe side. The dishwasher and washer values are typical figures inside the published fill-rate ranges (1.0 to 3.0 and 1.0 to 6.0 GPM), so check your appliance manuals. Incoming temperature. The coldest water of the year sets the size. Shallow groundwater temperature runs from the 30s and 40s in the far north to the 70s in the south, and the Building America Solution Center page on gas-fired tankless water heaters has a map of it by region. 50°F is a placeholder you should replace with your own figure. What this is not. It is not a plumber’s design. It does not cover how long hot water takes to reach a distant tap, minimum flow to fire (about 0.5 GPM for many units), pipe sizing, venting and gas line capacity, electrical service, codes or permits. The data sheet of the unit gives its flow at several temperature rises; compare it to the flow and rise above.
- US Department of Energy, Energy Saver, Tankless or Demand-Type Water Heaters: tankless units generally deliver 2 to 5 gallons per minute, and a 70°F rise is typically possible at about 5 GPM for gas-fired units and 2 GPM for electric ones; faster flow or cooler incoming water can reduce the temperature at the farthest tap
- US Department of Energy, Building America, Tankless Water Heaters: typical end-use flow rates (bath sink 0.5 to 1.5 GPM, bathtub 2.0 to 4.0, showerhead 1.5 to 2.5, kitchen sink 1.0 to 2.5, dishwasher 1.0 to 3.0) and the minimum flow of about 0.5 GPM a tankless unit needs to fire
- Pacific Northwest National Laboratory, Building America Solution Center, Gas-Fired Tankless Water Heaters: size from the winter cold water temperature and the setpoint, using the map of the average temperature of shallow groundwater by region; do not assume every fixture runs at once, find the practical maximum flow
- Pacific Northwest National Laboratory, Building America Solution Center, Instantaneous Water Heater Sizing tool: fill rates from the ASHRAE Handbook of Fundamentals of 1.0 to 3.0 GPM for a dishwasher and 1.0 to 6.0 GPM for a clothes washer, and the advice to choose a heater whose input rate is at least the calculated result
- Noritz, Tankless Sizing guide (printable): a worked sizing table that counts a dishwasher and a washing machine at 2 GPM each, in line with the typical 1.5 and 2.0 GPM used here
- US EPA WaterSense, Specification for Showerheads (supporting statement): the WaterSense label means 2.0 GPM or less, 20 percent below the 2.5 GPM federal maximum set by the Energy Policy Act of 1992
- US EPA WaterSense, Specification for Residential Bathroom Sink Faucets: a maximum flow of 1.5 GPM, 32 percent below the 2.2 GPM federal standard codified in 10 CFR Part 430
- US Department of Energy, Appliance and Equipment Standards, Faucets and showerheads, and 10 CFR 430.32 (Energy and water conservation standards): faucets 2.2 GPM at 60 psi (paragraph (o)) and showerheads 2.5 GPM at 80 psi (paragraph (p)). The paragraph letters were taken from a DOE summary and a rulemaking text; check the current eCFR text
- US Energy Information Administration, British thermal units (Btu): a Btu is the heat needed to raise one pound of liquid water one degree Fahrenheit, and 1 kilowatthour = 3,412 Btu
- Eccotemp, Electric Tankless Water Heater Installation Requirements: an example from one manufacturer’s manual, with an 11 kW unit on one 50 A breaker, an 18 kW unit on two 40 A breakers and a 27 kW unit on three 40 A breakers, all on 8 AWG copper; it stresses that these apply to the listed models only
- Typical figures on this page, not taken from a data sheet: the 95% (condensing) and 82% (non-condensing) efficiencies, the 1.5 GPM dishwasher and 2.0 GPM washer flows, the 120°F setpoint and the 50°F placeholder groundwater temperature. Use the rating on the data sheet of the unit you are considering
How to size a tankless water heater
- Add the flow. List the fixtures that run at the same time at your busiest moment and add their GPM: a showerhead is 1.5 to 2.5 GPM, a bathroom faucet 1.5 and a kitchen faucet up to 2.2.
- Find the temperature rise. Subtract your coldest incoming water temperature from the hot water temperature you want (120°F is usual).
- Convert to BTU/h. Multiply 500.4 by the GPM and by the rise to get the heat into the water in BTU/h.
- Gas or electric. For gas divide by the unit’s efficiency to get the input in BTU/h; for electric divide by 3,412.14 to get kW.
- Check the unit. Compare the unit’s data sheet flow at your temperature rise with the flow you need, and for electric check the circuits and panel with an electrician.
Worked examples
| Project | Result |
|---|---|
| Two showers at 2.0 GPM and a kitchen faucet, 50°F to 120°F, condensing gas | 228,600 BTU/h gas input (6.2 GPM × 500.4 × 70 ÷ 0.95) |
| The same load, non-condensing gas at 82% | 264,800 BTU/h gas input |
| The same load, electric | 63.6 kW electric (6.2 GPM × 500.4 × 70 ÷ 3,412.14) |
| A 199,000 BTU/h gas unit against the default load | 228,600 BTU/h gas input needed; the unit gives 5.4 GPM at a 70°F rise, short of 6.2 GPM |
| A 27 kW electric unit against the default load | 63.6 kW electric needed; the unit gives 2.63 GPM at a 70°F rise |
| A family: 2 showers, a bathroom faucet, the kitchen faucet, a dishwasher and a washer at once | 413,000 BTU/h gas input (11.2 GPM); electric 115 kW electric |
| Cold climate: the default load with 40°F incoming water | 261,300 BTU/h gas input (80°F rise) |
| Warm climate: the default load with 70°F incoming water | 163,300 BTU/h gas input (50°F rise) |
| One shower only, gas | 73,700 BTU/h gas input (2 GPM at a 70°F rise) |
Frequently asked questions
- What size tankless water heater do I need?
- Add up the flow of the fixtures that run at the same time, work out the temperature rise, and size the unit to deliver at least that flow at that rise. Two showers (2.0 GPM each) and a kitchen faucet (2.2 GPM) are 6.2 GPM; from 50°F to 120°F that needs 228,600 BTU/h gas input at 95% efficiency, or 63.6 kW electric. A family running two showers, a bathroom faucet, the kitchen faucet, the dishwasher and the washer together comes to 11.2 GPM and 413,000 BTU/h gas input.
- How do I calculate BTU/h for a tankless water heater?
- BTU/h into the water = 500.4 × GPM × temperature rise. The 500.4 is 60 minutes × 8.34 lb of water per gallon, and each pound takes 1 BTU per °F. For 6.2 GPM and a 70°F rise that is 217,200 BTU/h. A gas unit’s input is that divided by its efficiency: at 95% it is 228,600 BTU/h gas input, and at 82% (non-condensing) it is 264,800 BTU/h gas input.
- How do I convert GPM and temperature rise to kW?
- kW = 500.4 × GPM × rise ÷ 3,412.14, which is about GPM × rise ÷ 6.82. Electric resistance heating is about 100% efficient, so there is no efficiency term. For 6.2 GPM at 70°F the answer is 63.6 kW electric. That is about 265 A at 240 V, far more than one household circuit carries, which is why whole-house electric units are wired on several circuits.
- How many circuits does a whole-house electric tankless heater need?
- Several. A whole-house electric unit draws tens of kW, and one 240 V breaker is limited, so the load is split over dedicated circuits. One manufacturer’s installation manual lists an 11 kW unit on one 50 A breaker, an 18 kW unit on two 40 A breakers and a 27 kW unit on three 40 A breakers, and says these apply only to its listed models. Units of 36 kW and up need more again. Your unit’s manual gives the breaker sizes and wire, and the main panel may need an upgrade; have an electrician check this before you choose. The default load here is 63.6 kW electric, which is above any one of those example units.
- What groundwater temperature should I use?
- Use the temperature of the incoming cold water in your coldest month, because that is the hardest case for the heater. It follows shallow groundwater temperature, which runs from the 30s and 40s in the far north to the 70s in the south of the United States; the map on the Building America Solution Center page for gas-fired tankless water heaters shows it by region, and your water utility can tell you. The 50°F default is a placeholder. The effect is large: the default load at 40°F is 261,300 BTU/h gas input, and at 70°F it is 163,300 BTU/h gas input.
- What temperature rise do I need?
- The rise is the hot water temperature you want minus the incoming water temperature. At the usual 120°F setpoint and 50°F groundwater it is 70°F. DOE notes that a 70°F rise is typically possible at about 5 GPM from a gas-fired unit and about 2 GPM from an electric one, so flow and rise trade off: the same unit gives less flow at a higher rise.
- How many GPM do showers and faucets use?
- EPA WaterSense showerheads are 2.0 GPM or less, and the federal maximum is 2.5 GPM. A WaterSense bathroom faucet is 1.5 GPM or less against a federal 2.2 GPM, and 2.2 GPM is also the federal maximum for a kitchen faucet. Dishwasher and clothes washer fill rates range widely (1.0 to 3.0 and 1.0 to 6.0 GPM in the ASHRAE ranges), so this tool uses typical values of 1.5 and 2.0 GPM; check your appliance manuals. A fixture’s hot flow is lower than its rating whenever it mixes in cold water.
- How much flow does a unit I am considering give?
- Enter its gas input in BTU/h or its power in kW, and the tool shows the most flow it gives at your temperature rise: (input × efficiency) ÷ (500.4 × rise) for gas, (kW × 3,412.14) ÷ (500.4 × rise) for electric. A 199,000 BTU/h unit at 95% gives 5.4 GPM at a 70°F rise, short of the 6.2 GPM the default load needs; a 27 kW electric unit gives 2.63 GPM. A real unit’s data sheet shows its tested flow by rise and is the figure to trust.
- Gas or electric tankless: which size should I use?
- Use the line for your fuel. The gas figure is the burner’s input, the number on the unit’s data plate, and it already allows for the efficiency you enter. The electric figure is the power drawn. The same load, 6.2 GPM at 70°F, is 228,600 BTU/h gas input for gas and 63.6 kW electric for electric. A gas unit also needs venting and enough gas supply, and an electric one needs the circuits and panel capacity above.
- Should I count every fixture in the house?
- No. Count only the fixtures that really run together at your busiest moment. One shower and nothing else is 2 GPM and 73,700 BTU/h gas input; a unit sized for every fixture at once would be larger and cost more for a peak that rarely happens. The cost of counting too few is lukewarm water or a unit that cannot keep up when two fixtures run, so count the realistic worst case, such as two showers and the kitchen faucet. With federal-maximum 2.5 GPM showerheads the default load becomes 7.2 GPM and 265,500 BTU/h gas input.
- What efficiency should I enter for a gas unit?
- The tool defaults to 95% for a condensing unit and offers 82% as the figure for a non-condensing unit. These are typical estimates, so use the UEF or thermal efficiency on the data sheet of the unit you are considering. The default load needs 228,600 BTU/h gas input at 95% and 264,800 BTU/h gas input at 82%. Electric units are taken as 100% efficient.
- How is this different from the water heater size calculator?
- The water heater size calculator covers both a storage tank, sized by First Hour Rating from your busiest hour, and a basic tankless estimate. This page goes further for tankless: more fixtures including a dishwasher and a washer, the 500.4 constant and 3,412.14 BTU per kWh, a condensing or non-condensing efficiency, and the most flow a unit you choose gives at your rise.