Skip to main content
ponderloop

Landscape Lighting Transformer Calculator: What Size Transformer and Cable?

Twelve 10 W fixtures are 120 W. Keeping the load at or under 80% of the rating means a transformer of at least 150 W, so 150 W transformer (the next standard size). On 100 ft of 12/2 cable that carries all 120 W, the 12 V cable loses about 2.15 V with the lights spread along the run, leaving 9.86 V at the last fixture. That is under the 10.5 to 11.5 V that makers aim for, so the calculator suggests 2 runs of 6 fixtures (about 1.16 V lost on each) or a thicker cable. The 120 V side draws about 1 A. The 80% rule and the voltage window are manufacturer guidance, not code, and your fixture maker’s instructions come first.

Figures based on the sources listed belowUpdated How we calculate

Every light on the transformer. Count a fixture with two lamps as the watts of both.

The watts printed on the fixture or lamp. For LED fixtures use the VA rating if the maker gives one: it is the number that loads the transformer.
Low-voltage landscape cable is named by the gauge of its two conductors. Lower numbers are thicker and lose less voltage.

The cable length one way, from the transformer to the last fixture on the longest run. The cable out and back is worked for you.
Lights spread evenly along a run lose about half the voltage that the same lights bunched at the end do. Choose the worst case if you are unsure.
Multi-tap transformers have 12 V and higher terminals to make up for voltage drop. Check your fixtures’ maximum voltage first: some makers allow 14 or 15 V at most.
FX Luminaire’s installation guides aim for 10.5 to 11.5 V at every fixture. Use your fixture maker’s figure if it differs.

150 W transformer.

150 W transformer

  • Total load: 120 W (VA): 12 × 10, which is 10 A at 12 V
  • Smallest transformer at the 80% rule: 150 W (120 ÷ 0.8)
  • Transformers: 150 W, loaded to 80% with 120 W
  • Voltage at the last fixture: 9.86 V (2.15 V lost on 100 ft of 12/2 carrying all 120 W). That is below your 10.5 V minimum: see the runs line
  • Runs from the transformer: 2 equal runs of 6 fixtures: about 1.16 V lost on each, 10.85 V at the last fixture, 60 W on each cable. Feed them from separate terminals or a hub
  • 120 V circuit: 1 A at your load; 1.25 A if the transformer ran at its full rating (150 W ÷ 120 V). Both are small beside a 15 A circuit

Shopping list

  • Low-voltage landscape lighting transformer, 300 W
  • 12/2 low-voltage landscape cable
  • 10/2 low-voltage landscape cable
  • LED landscape path lights
  • Digital multimeter (check the voltage at the fixture)

Saved projects

No saved projects yet.

Standard transformer sizes and their 80% load

Typical ratings in watts (VA). The 80% column is the most load the rating should carry under the 80% rule; the amps columns are the current at the full rating in the 12 V secondary and in the 120 V primary.
TransformerLoad at 80%12 V amps at full rating120 V amps at full rating
75 W60 W6.3 A0.63 A
100 W80 W8.3 A0.83 A
150 W120 W12.5 A1.25 A
300 W240 W25 A2.5 A
600 W480 W50 A5 A
900 W720 W75 A7.5 A
1,200 W960 W100 A10 A

Longest run by cable gauge

One-way length in feet for a 1.5 V drop (12 V tap, 10.5 V at the fixture) with the whole load at the far end, the worst case. Fixtures spread along the run can go further. Worked from the NEC Table 8 copper resistance.
Load on the run12/210/28/2
60 W75 ft120 ft192 ft
100 W45 ft72 ft115 ft
150 W30 ft48 ft77 ft
200 W22 ft36 ft57 ft
300 W15 ft24 ft38 ft

Landscape cable data

Resistance of one conductor and of the out-and-back pair in ohms per 1,000 ft of run (NEC Chapter 9 Table 8, copper), and VOLT’s suggested maximum load on one run.
CableOhms per 1,000 ft (one conductor)Ohms per 1,000 ft (out and back)Suggested maximum load
12/21.983.96100 W
10/21.242.48144 W
8/20.7781.556300 W

Methodology & assumptions

A landscape lighting system is a transformer that steps 120 V down to 12 V, and cable that carries the 12 V out to the lights. This tool sizes the transformer, then checks the cable. 1) Load = fixtures × watts (or VA) per fixture. For LED fixtures use the VA rating when the maker gives one, because VA is what loads the transformer. VOLT’s installation manual advises dividing an LED load in watts by a power factor of 0.7 and keeping the load under 70% of the capacity, a more cautious rule than the 80% used here, so use it if your fixtures only list watts and your transformer is nearly full. 2) Minimum transformer = load ÷ 0.8. VOLT’s product pages recommend not exceeding 80 percent of a transformer’s capacity. Kichler’s guide is simpler: add the lamp wattages, pick the closest transformer, and keep the load between one third of the rating and the rating, so Kichler’s method can choose a smaller transformer than this page does. Some trade articles attribute the 80% to the National Electrical Code, but we could not confirm that in the code text, so this page treats it as manufacturer practice. Hinkley advises adding about 20% for future lights, which the 80% rule gives you by itself. 3) The transformer is the smallest standard size at or above the minimum: 75, 100, 150, 300, 600, 900, 1,200 W. These are typical ratings from the makers’ ranges (FX Luminaire lists 150, 300, 600 and 900 W units, Kichler has listed 75, 100, 300, 600, 900 and 1,200 W), not a complete list, so check what your brand sells. Above 1,200 W of minimum the tool shows several transformers and you split the fixtures between them. 4) Cable current = load ÷ 12 V. The cable is two conductors, so the drop is current × 2 × length × ohms per 1,000 ft ÷ 1,000. The resistance is copper at 75 °C for stranded conductors, the NEC Chapter 9 Table 8 values the voltage drop calculator uses: 12 AWG 1.98, 10 AWG 1.24 and 8 AWG 0.778 ohms per 1,000 ft. Outdoor cable is cooler than 75 °C, so its real resistance is a little lower, a small margin of safety. 5) Layout. With every fixture at the far end the whole current flows the whole length. With n fixtures spread evenly along the run, the last at the end, the drop is (n + 1) ÷ (2n) of that. 6) Voltage at the last fixture = transformer tap − drop, compared with the minimum you choose. FX Luminaire’s installation guides aim for 10.5 to 11.5 V at each fixture, and another of its guides recommends 11 to 11.5 V for predictable lamp life; a JLC Online article says 12 V lamps work at 10 to 11 V. The allowed drop on a 12 V tap is therefore 1.5 V at a 10.5 V minimum. A higher tap raises the allowance, up to the highest voltage your fixtures accept: FX warns against some of its fixtures on a transformer whose secondary exceeds 14 V, and UL 1838 caps a garden-lighting secondary at 15 V. The fixtures nearest the transformer see the tap voltage, so a high tap can over-drive a short run of lamps. 7) Runs. The tool finds the fewest equal runs, with the fixtures divided evenly, for which the last fixture on each run stays above the minimum and the load on each cable stays within VOLT’s suggested maximum for it (12/2 100 W, 10/2 144 W, 8/2 300 W). That load figure comes from VOLT’s installation manual as published, and it is a manufacturer guideline for one cable, not a code limit. A hub, or separate cables from separate terminals, lets several runs share a transformer. 8) The 120 V side: the transformer’s primary current is its load ÷ 120 V. The tool shows it at your load and at the transformer’s full rating (rating ÷ 120 V), ignoring transformer losses and power factor, which add a little. Outdoor circuits generally need ground-fault protection and weather-rated parts: follow your local code and the transformer’s manual. What this does not do: it assumes equal fixtures on equal runs, treats current as load ÷ 12 V whatever the drop (an LED driver draws a little more current as voltage sags, an incandescent lamp a little less), and ignores connectors, splices and smart-controller loads. A multimeter reading at the last fixture with every lamp on is the real test.

How to size a landscape lighting transformer

  1. Add up the load. Multiply the number of fixtures by the watts (or VA) on each fixture label. Add different fixtures together.
  2. Apply the 80% rule. Divide the total by 0.8 and choose the next standard transformer size above it: 100, 150, 300, 600, 900 or 1,200 W.
  3. Choose the cable. Pick 12/2, 10/2 or 8/2 and enter the one-way length from the transformer to the last fixture on the longest run.
  4. Check the voltage at the last fixture. Aim for 10.5 to 11.5 V with all the lamps on. If it is low, use a thicker cable, split the fixtures into more runs, shorten the run or raise the tap.
  5. Check the 120 V side. Divide the transformer rating by 120 for the amps it can draw and make sure the circuit and its protection suit that.
  6. Measure when installed. With a multimeter at the farthest fixture and all lamps on, confirm the voltage, and move the tap if it needs it.

Worked examples

ProjectResult
12 fixtures of 10 W on 100 ft of 12/2, spread along the run150 W transformer; 9.86 V at the last fixture on one run, so 2 runs
The same job on 10/2 cable150 W transformer; 10.66 V at the last fixture, 1 run
The same job with every fixture at the far end of the run150 W transformer; 8.04 V at the last fixture, 3 runs
Kichler’s guide example: 11 fixtures of 24.4 W on 60 ft of 10/2600 W transformer at the 80% rule (Kichler’s own method picks 300 W); 10.18 V at the last fixture
20 LED path lights of 4 W on 80 ft of 12/2100 W transformer; 10.89 V at the last fixture, 1 run
8 floodlights of 20 W on 40 ft of 12/2300 W transformer; 10.81 V at the last fixture, 2 runs
30 fixtures of 20 W on 150 ft of 8/2900 W transformer; 5.97 V at the last fixture, 5 runs
60 fixtures of 20 W on 120 ft of 8/22 × 1,200 W transformers

Frequently asked questions

What size transformer do I need for landscape lighting?
Add up the watts (or VA) of every fixture, divide by 0.8, and take the next standard size up. Twelve 10 W fixtures are 120 W; ÷ 0.8 is 150 W, so 150 W transformer. Sixty 20 W fixtures are 1,200 W, which needs 2 × 1,200 W transformers.
What is the 80% rule for landscape lighting transformers?
Keep the connected load at or under 80% of the transformer’s rating, so a 300 W transformer carries up to 240 W. VOLT recommends not exceeding 80 percent of capacity. It leaves room for more lights later. Kichler’s guide uses a simpler match-the-wattage method, so check your brand’s instructions.
Do I use watts or VA for LED fixtures?
Use the VA rating when the maker gives one: it is the load the transformer feels. LED fixtures often list watts only, and an LED driver can draw more VA than its watts. VOLT’s manual divides an LED load in watts by a power factor of 0.7 and keeps the result under 70% of capacity. If your transformer would be close to full, work it that way too. To light a room, work in lumens instead: the room lighting calculator turns a room’s size into lumens and bulbs.
How much voltage should reach the fixtures?
About 10.5 to 11.5 V at every fixture with all the lamps on, according to FX Luminaire’s installation guides, which is why this tool lets you pick 10.5, 11 or 11.5 V as the minimum. A 12 V tap with a 10.5 V minimum allows 1.5 V of drop. Low voltage dims a lamp and can shift the colour of, or switch off, some LED fixtures.
How do I reduce voltage drop?
Use a thicker cable, shorten the run, spread the lights along it, split the fixtures into more runs, or use a higher tap on a multi-tap transformer. Going from 12/2 to 10/2 on the default job takes the last fixture from 9.86 V to 10.66 V; a 14 V tap lifts it to 11.86 V, though the nearest lights then see 14 V.
How many runs do I need?
The tool divides the fixtures into equal runs until the last fixture on each stays above your minimum voltage and each cable is within VOLT’s suggested load for it (12/2 100 W, 10/2 144 W, 8/2 300 W). The default job needs 2 runs. With all the fixtures bunched at the end of the 100 ft run it needs 3 runs.
What is a hub?
A fitting that joins several cables to one pair of transformer terminals, so each run can have its own home-run cable. Without one, runs are wired to separate terminals. Either way, each run carries only its own share of the load, which is what keeps the drop down.
What if I need more than 1,200 W?
Use more than one transformer and split the fixtures between them, each with its own runs. Sixty 20 W fixtures need at least 1,500 W at the 80% rule, which the tool shows as 2 × 1,200 W transformers. Placing the transformers near their lights also shortens every run.
How many amps does the transformer draw from the 120 V circuit?
Load ÷ 120 V. Twelve 10 W fixtures draw about 1 A, and even a full 1,200 W transformer is 10 A, so a standard 15 A circuit is plenty. The tool also shows the amps at the transformer’s full rating, which is the safe figure for sizing the circuit. Outdoor circuits generally need ground-fault protection: follow your local code.
Is Kichler’s method different?
Yes. Kichler’s guide adds the lamp wattages and picks the closest transformer, keeping the load between a third of the rating and the rating. Its example is 11 fixtures at 24.4 W (268 W) on a 300 W transformer. With the 80% rule the same lights need 600 W transformer. Follow your brand’s guide for the warranty; the 80% rule is the cautious choice.