How Many Lumens Do I Need? (Room Lighting Calculator)
A 14 × 12 ft kitchen is 168 sq ft. At 35 foot-candles, the middle of the typical 30 to 40 range for kitchen general light, that is 5,880 lumens: 168 sq ft × 35 lumens per sq ft. With 800 lumen bulbs (the usual 60 W replacement) that is 8 bulbs, and about 71 W of LED at a typical 90 lumens per watt. Pick the room type, the bulb size on the box and the brightness to change it. The light levels are typical figures from published guides, not code, and bulbs differ: use the lumens and watts printed on the bulb you buy.
Figures based on the sources listed belowUpdated How we calculate
5,880 lumens.
5,880 lumens
- Target light level: 35 fc (about 377 lux) for a kitchen (general light), within its typical 30 to 40 fc
- Bulbs: 8 bulbs (800 lumens each, total 6,400 lumens)
- Fixtures: 8 fixtures, 1 bulb each
- LED watts: 71 W in all (8.9 W a bulb at 90 lm/W), 0.42 W per sq ft
- Room area: 168 sq ft
- Task lighting: Counters, sink and stove are task areas that guides put at 50 to 100 fc: add under-cabinet or pendant light for them.
Shopping list
- LED bulbs (A19, 800 lumens)
- LED recessed lighting retrofit kit
- LED under-cabinet lights
- Dimmer switch (LED compatible)
- Light meter (lux)
Your project
- Room length × room width: 14 × 12 ft
- Room type: Kitchen (general light)
- Brightness: Middle of the range
- Light output of one bulb: 800 lumens (60 W incandescent)
- Bulbs per fixture: 1
- LED efficacy: 90 lm/W (typical LED bulb)
Also pick up
- LED bulbs (A19, 800 lumens)
- LED recessed lighting retrofit kit
- LED under-cabinet lights
- Dimmer switch (LED compatible)
- Light meter (lux)
Reopen this calculation: /calculators/room-lighting/?s=eyJyb29tIjp7Imxlbmd0aEZ0IjoxNCwid2lkdGhGdCI6MTJ9LCJkZWR1Y3Rpb25zIjpbXSwid2FzdGVQY3QiOjAuMSwicGFyYW1zIjp7InJvb21UeXBlIjoxLCJsZXZlbCI6MSwiYnVsYkx1bWVucyI6ODAwLCJidWxic1BlckZpeHR1cmUiOjEsImVmZmljYWN5Ijo5MH19
Show diagram
Saved projects
No saved projects yet.
Typical light levels by room
| Room type | Foot-candles | Lux | Middle (fc) |
|---|---|---|---|
| Kitchen (general light) | 30 to 40 | 323 to 431 | 35 |
| Living room | 10 to 20 | 108 to 215 | 15 |
| Bedroom | 10 to 20 | 108 to 215 | 15 |
| Bathroom | 20 to 50 | 215 to 538 | 35 |
| Dining room | 30 to 40 | 323 to 431 | 35 |
| Home office or reading room | 30 to 50 | 323 to 538 | 40 |
| Hallway or entry | 5 to 20 | 54 to 215 | 12.5 |
Lumens, bulbs and LED watts for common rooms
| Room | Sq ft | fc | Lumens | Bulbs | LED watts |
|---|---|---|---|---|---|
| Kitchen, 14 × 12 ft | 168 | 35 | 5,880 | 8 | 71 W |
| Living room, 20 × 15 ft | 300 | 15 | 4,500 | 6 | 53 W |
| Bedroom, 12 × 12 ft | 144 | 15 | 2,160 | 3 | 27 W |
| Bathroom, 8 × 5 ft | 40 | 35 | 1,400 | 2 | 18 W |
| Dining room, 12 × 14 ft | 168 | 35 | 5,880 | 8 | 71 W |
| Home office, 10 × 10 ft | 100 | 40 | 4,000 | 5 | 44 W |
| Hallway, 20 × 4 ft | 80 | 12.5 | 1,000 | 2 | 18 W |
Bulb lumens and LED watts
| Lumens per bulb | LED watts at 90 lm/W | LED watts at 120 lm/W | Bulbs for the kitchen |
|---|---|---|---|
| 450 | 5 W | 3.8 W | 14 |
| 800 | 8.9 W | 6.7 W | 8 |
| 1,100 | 12.2 W | 9.2 W | 6 |
| 1,600 | 17.8 W | 13.3 W | 4 |
| 2,600 | 28.9 W | 21.7 W | 3 |
Methodology & assumptions
One foot-candle is one lumen on one square foot, so the light a room needs is its area times a target in foot-candles. 1) Area = length × width, in sq ft. 2) Target = a typical average light level for the room type, in foot-candles. This tool uses the residential ranges from Penn State’s EGEE 102 course notes (“How Much Lighting is Needed”): living rooms and bedrooms 10 to 20; dining rooms 30 to 40; kitchens 30 to 40 for general light (50 to 100 at the counters, sink and stove); bathrooms 20 to 50; halls and entries 5 to 20; reading and writing about 50, with 30 to 50 the most ambient light one generally needs. The “middle” setting is the average of the two ends, and you can choose either end. These ranges are the usual residential recommendations that lighting guides trace to the Illuminating Engineering Society (IES). We could not open the IES Lighting Handbook itself, which is sold, so this page does not quote it, and lighting sites that cite it give somewhat different ranges for the same rooms (bedrooms are the most spread), so treat every level as a typical figure and not as code or a design standard. 3) Total lumens = area × target, rounded to a whole lumen. 4) Bulbs = total lumens ÷ the lumens of one bulb, rounded UP to a whole bulb. Fixtures = bulbs ÷ bulbs per fixture, rounded up; if that leaves a part-empty fixture the tool counts it full, so the lumens shown on the bulbs line can be a little over the target. 5) LED watts = installed bulbs × bulb lumens ÷ efficacy in lumens per watt (lm/W). The efficacy choices are a minimum and a range, not a measurement of your bulb: ENERGY STAR’s Lamps Version 2.0 specification sets minimums of 70 lm/W for omnidirectional bulbs with a CRI of 90 or more and 80 lm/W for other omnidirectional bulbs; 90 lm/W is this site’s typical figure for an LED bulb today; 120 lm/W is a very efficient one. DOE’s 2024 general service lamp rule will raise the legal minimum for common bulbs to between 83 and 195 lm/W by lamp type from July 25, 2028. The 2013 DOE snapshot that tested 60 W-equivalent LED bulbs found less than 60 to nearly 90 lm/W, so an old bulb in your drawer may be well under the typical figure. Lux is foot-candles × 10.764 (1 lm per sq ft is 10.764 lm per sq m); the result stays in lumens and foot-candles under the metric switch, with lux shown beside them, and only the room size changes to meters. What this does not count: ceiling height (a high ceiling, dark walls and floors, and heavy shades all absorb light, so such a room needs the high end), how much of a fixture’s light reaches the room (an uplight, a shade or a frosted globe loses some), colour temperature, dimming, and the pattern of light (the easy way to a good room is layers: general light plus task lamps where you read, cook and groom). Bulb lumens of 450, 800, 1,100, 1,600 and 2,600 are the usual box figures for 40, 60, 75, 100 and 150 W incandescent replacements; DOE gives 450, 800 and 1,600 for 40, 60 and 100 W.
- Penn State, EGEE 102 Energy Conservation, 8.3 How Much Lighting is Needed: the residential light levels in foot-candles by room (living rooms and bedrooms 10 to 20, kitchen 30 to 40 general and 50 to 100 at the task areas, dining 30 to 40, bathrooms 20 to 50, halls 5 to 20), and about 50 fc for reading and writing. These were not checked against the full page; other lighting guides give slightly different ranges
- U.S. Department of Energy, Energy Saver, Lumens and Lighting Facts: choose a bulb by lumens, not watts; about 800 lumens replaces a 60 W incandescent bulb, 450 lumens a 40 W bulb and 1,600 lumens a 100 W bulb
- ENERGY STAR, Lamps Version 2.0 webinar slides: the minimum luminous efficacy for omnidirectional lamps, 70 lm/W with a CRI of 90 or more and 80 lm/W with a CRI under 90 (read from the slide deck, not from the final specification text, so check energystar.gov/lamps before relying on the figure)
- U.S. Department of Energy, Energy Conservation Program: Energy Conservation Standards for General Service Lamps, final rule (Federal Register, April 19, 2024, 89 FR 28856): compliance from July 25, 2028. The 83 to 195 lm/W range is as reported by lighting trade press; the rule text sets the level by lamp type
- U.S. Department of Energy, Solid-State Lighting, Adoption of Light-Emitting Diodes in Common Lighting Applications (the 2013 A-lamp snapshot): LED bulbs matching a 60 W incandescent ranged from under 60 to nearly 90 lm/W. A 2013 figure, so today’s bulbs are generally better
- Assumptions made for this calculator, not from a published source: the middle of each range as the default level, 90 lm/W as a typical LED bulb, 110 and 120 lm/W as efficient bulbs, and counting a part-empty fixture as full. Retail lighting guides (for example Super Bright LEDs’ residential recommended lighting levels) quote ranges that differ for some rooms
How to work out the lumens a room needs
- Measure the room. Measure the length and width in feet and multiply to get square feet.
- Pick the light level. Choose a target in foot-candles (lumens per sq ft) for the room: 10 to 20 for living rooms and bedrooms, 30 to 40 for dining rooms and kitchens, 20 to 50 for bathrooms, 5 to 20 for halls.
- Multiply. Lumens needed = square feet × foot-candles.
- Count the bulbs. Divide by the lumens printed on the bulb box and round up. Divide that by the bulbs in each fixture for the number of fixtures.
- Check the watts. Watts = lumens ÷ the bulb’s lumens per watt. Use the box for the real figure. Add task lamps where you read, cook or groom.
Worked examples
| Project | Result |
|---|---|
| 14 × 12 ft kitchen, middle of the range, 800 lumen bulbs | 5,880 lumens, 8 bulbs, about 71 W of LED |
| The same kitchen at the low end of the range | 5,040 lumens, 7 bulbs |
| The same kitchen at the high end, with 1,600 lumen bulbs | 6,720 lumens, 5 bulbs |
| 20 × 15 ft living room | 4,500 lumens, 6 bulbs of 800 lumens (300 sq ft) |
| 12 × 12 ft bedroom | 2,160 lumens, 3 bulbs (144 sq ft) |
| 8 × 5 ft bathroom | 1,400 lumens, 2 bulbs (40 sq ft) |
| 12 × 14 ft dining room | 5,880 lumens, 8 bulbs (168 sq ft) |
| 10 × 10 ft home office at the high end of its range | 5,000 lumens, 7 bulbs (100 sq ft at 50 fc) |
| 20 × 4 ft hallway | 1,000 lumens, 2 bulbs (80 sq ft) |
Frequently asked questions
- How many lumens do I need for a room?
- Multiply the floor area in sq ft by a target in foot-candles (lumens per sq ft) for the room type. A 14 × 12 ft kitchen is 168 sq ft; at 35 fc that is 5,880 lumens, at the low end (30 fc) 5,040 lumens and at the high end (40 fc) 6,720 lumens. A 20 × 15 ft living room at 15 fc is 4,500 lumens.
- How many lumens per square foot is that?
- The same thing as foot-candles. Typical home figures are about 10 to 20 for living rooms and bedrooms, 30 to 40 for dining rooms and kitchen general light, 20 to 50 for bathrooms and 5 to 20 for halls. Reading and writing want about 50.
- What is the difference between foot-candles and lux?
- Both measure the light that lands on a surface. A foot-candle is one lumen per square foot and a lux is one lumen per square meter, so 1 fc is 10.76 lux. The kitchen’s 35 fc is about 377 lux.
- How many bulbs do I need?
- Divide the lumens by the lumens of one bulb and round up. The kitchen’s 5,880 lumens takes 8 bulbs of 800 lumens, or 4 of 1,600. If a fixture holds three bulbs, 3 fixtures give 9 bulbs. Spread them evenly rather than putting them all in the middle.
- How many watts is that in LED bulbs?
- Lumens ÷ lumens per watt. At a typical 90 lm/W the 8 bulbs of 800 lumens are 71 W in all (8.9 W a bulb), and at 120 lm/W 53 W. Efficacy varies by bulb, so use the watts on the box. A 60 W incandescent bulb gives the same 800 lumens.
- Why choose bulbs by lumens and not watts?
- Watts measure the power a bulb uses, and lumens the light it gives. An LED bulb that gives the light of a 60 W incandescent bulb, about 800 lumens, uses only a fraction of the power. The U.S. Department of Energy advises buying by lumens. Look for the Lighting Facts label on the box.
- Is it the same for every room, even with a high ceiling or dark walls?
- No. These are averages for a room with a normal ceiling and light surfaces. A high ceiling, dark walls and floors, a shade or a frosted globe all absorb light, so use the high end of the range, or more. Older eyes also need more light. The low end suits a room you only pass through or that you light in layers with lamps.
- What about task lighting?
- The room figure is the general light. Places where you work need more: kitchen counters, sink and stove 50 to 100 fc, a desk or a reading chair about 50 fc, and a bathroom mirror. Add under-cabinet lights, a desk lamp or vanity lights for those instead of raising the whole room. A home office or reading room of 10 × 10 ft at the high end of its range is 5,000 lumens. For outdoor path and garden lights, use the landscape lighting transformer calculator, which sizes the transformer and cable.
- Where do these light levels come from?
- They are typical residential ranges as listed in the Penn State EGEE 102 course notes, the kind of figures lighting guides attribute to the Illuminating Engineering Society (IES). The IES Lighting Handbook is sold and not free to read, and guides that cite it differ a little, so treat the numbers as typical figures. For a design or a workplace, use a lighting designer and the current IES standard.
Handy tools
- Electricity Cost Calculator: Turn the watts into a bill: it prices a load by hours a day and your rate per kWh.