Pool Heater Size Calculator: How Many BTU/h Do You Need?
A 20,000 gallon, 500 sq ft pool that you want to warm from 65 to 82 °F (17 °F) in 24 hours with an 82% efficient gas heater needs 145,000 BTU/h of input for the heat-up alone: 20,000 gal × 8.34 lb × 17 °F = 2,835,600 BTU, ÷ 24 h = 118,150 BTU/h into the water, ÷ 0.82. Holding that temperature outdoors when the coldest month averages 60 °F is the larger job by the U.S. Department of Energy’s rule of thumb (surface area × temperature difference × 12 = 132,000 BTU/h into the water), so the calculator suggests 161,000 BTU/h of input, and the next common heater size is 175,000 BTU/h. Enter your own volume, area, temperatures, hours and efficiency; test any heater size to see how long it takes. These are estimates: wind, humidity, cool nights and a cover change the real load.
Figures based on the sources listed belowUpdated How we calculate
161,000 BTU/h.
161,000 BTU/h
- Heater input needed: 161,000 BTU/h
- Which one to buy: 161,000 BTU/h (set by the surface-area method; the next common size is 175,000 BTU/h)
- Heat-up in the time you set: 145,000 BTU/h input (119,000 BTU/h into the water, 34.6 kW): 20,000 US gal × 8.34 lb × 17 °F ÷ 24 h ÷ 82%
- Heat to add: 2,835,600 BTU (831 kWh of heat) to raise 20,000 US gal by 17 °F
- Surface-area method (DOE): 161,000 BTU/h input (132,000 BTU/h into the water): 500 sq ft × 22 °F × 12 ÷ 82%
- Heat-up time with your heater: about 13 h 50 min with a 250,000 BTU/h heater at 82% (0.6 days); the real time is longer because the pool loses heat while it warms
- Your heater against the surface-area load: a 250,000 BTU/h heater at 82% puts 205,000 BTU/h into the water, 155% of the 132,000 BTU/h the DOE method gives: at or above the DOE surface-area figure, so it should hold the target at that warm-up rate
- Temperature check: 65 to 82 °F is a rise of 17 °F; the target is 22 °F above the coldest-month air
Shopping list
- Pool thermometer
- Solar pool cover
- Liquid pool cover (evaporation)
Your project
- Pool volume: 20,000
- Volume unit: US gallons
- Pool surface area: 500
- Area unit: Square feet
- Temperature unit: Degrees Fahrenheit (°F)
- Current water temperature: 65
- Desired water temperature: 82
- Coldest-month average air temperature: 60
- Time to heat up: 24 hours
- Heater efficiency: 82 %
- Warm-up rate for the surface-area method: 1 to 1.25 °F per hour (about 0.6 to 0.7 °C per hour)
- Heater size to test: 250,000 BTU/h
Also pick up
- Pool thermometer
- Solar pool cover
- Liquid pool cover (evaporation)
Reopen this calculation: /calculators/pool-heater-size/?s=eyJyb29tIjp7Imxlbmd0aEZ0IjowLCJ3aWR0aEZ0IjowfSwiZGVkdWN0aW9ucyI6W10sIndhc3RlUGN0IjowLjEsInBhcmFtcyI6eyJwb29sVm9sdW1lIjoyMDAwMCwidm9sdW1lVW5pdCI6MCwic3VyZmFjZUFyZWEiOjUwMCwiYXJlYVVuaXQiOjAsInRlbXBVbml0IjowLCJjdXJyZW50VGVtcCI6NjUsInRhcmdldFRlbXAiOjgyLCJhaXJUZW1wIjo2MCwiaG91cnMiOjI0LCJlZmZpY2llbmN5Ijo4MiwicmF0ZU11bHRpcGxpZXIiOjAsImhlYXRlckJ0dSI6MjUwMDAwfX0
Saved projects
No saved projects yet.
Heater input to heat a pool in 24 hours
| Pool volume | 10 °F rise | 15 °F rise | 20 °F rise |
|---|---|---|---|
| 10,000 gal | 43,000 BTU/h | 64,000 BTU/h | 85,000 BTU/h |
| 15,000 gal | 64,000 BTU/h | 96,000 BTU/h | 128,000 BTU/h |
| 20,000 gal | 85,000 BTU/h | 128,000 BTU/h | 170,000 BTU/h |
| 30,000 gal | 128,000 BTU/h | 191,000 BTU/h | 255,000 BTU/h |
| 40,000 gal | 170,000 BTU/h | 255,000 BTU/h | 340,000 BTU/h |
Surface-area method: heat into the water by pool area
| Surface area | 10 °F difference | 20 °F difference | 30 °F difference | 40 °F difference |
|---|---|---|---|---|
| 200 sq ft | 24,000 BTU/h | 48,000 BTU/h | 72,000 BTU/h | 96,000 BTU/h |
| 400 sq ft | 48,000 BTU/h | 96,000 BTU/h | 144,000 BTU/h | 192,000 BTU/h |
| 600 sq ft | 72,000 BTU/h | 144,000 BTU/h | 216,000 BTU/h | 288,000 BTU/h |
| 800 sq ft | 96,000 BTU/h | 192,000 BTU/h | 288,000 BTU/h | 384,000 BTU/h |
Heat-up time for a 20,000 gallon pool by heater size
| Heater input | 10 °F rise | 15 °F rise | 20 °F rise |
|---|---|---|---|
| 150,000 BTU/h | 13 h 34 min | 20 h 20 min | 27 h 7 min |
| 250,000 BTU/h | 8 h 8 min | 12 h 12 min | 16 h 16 min |
| 400,000 BTU/h | 5 h 5 min | 7 h 38 min | 10 h 10 min |
Methodology & assumptions
Two separate questions are answered, and the heater has to cover the larger. 1) Heat-up. One BTU raises one pound of water one degree Fahrenheit, and a US gallon of water weighs 8.34 lb, so the heat to add is gallons × 8.34 × the rise in °F. For the default pool that is 20,000 × 8.34 × 17 = 2,835,600 BTU (831 kWh of heat). Divide by the hours you can wait to get the BTU/h that must reach the water (118,150), and by the heater’s efficiency to get the input rating on the nameplate (144,085 at 82%, rounded up to 145,000 BTU/h). Pentair’s engineering data sheet states the same relation for the heat-up time: gallons × 8.34 lb per gallon × temperature rise × 60 minutes ÷ (heater BTU/h input × efficiency). This ignores the heat the pool loses to the air while it warms (surface evaporation, wind, cool nights), so the real time is longer than the figure; treat the heat-up result as a minimum. 2) Holding the temperature outdoors. The U.S. Department of Energy’s Energy Saver page on gas pool heaters gives a rough method for an outdoor pool: take the desired water temperature, subtract the average air temperature of the coldest month you will swim in to get the temperature difference, measure the pool’s surface area in square feet, and multiply area × difference × 12 to get BTU/h. The 12 is based on a warm-up of 1 to 1 1/4 °F per hour and an average wind of 3 1/2 mph at the pool surface; for a warm-up of 1 1/2 °F per hour multiply by 1.5 and for 2 °F per hour multiply by 2. The page also says wind, humidity and cool nights affect the load and that a trained pool professional should do a proper analysis, so this is an approximation and the calculator labels it an estimate. For the default pool: 500 sq ft × 22 °F × 12 = 132,000 BTU/h. DOE does not say whether that figure is the heater’s output or its input rating; this calculator treats it as heat delivered into the water and divides by the efficiency to get an input rating, which is the cautious reading (161,000 BTU/h at 82%). The suggested size is the larger of the two inputs, rounded up to the next 1,000 BTU/h; the next common size is read from a list of typical gas heater inputs (100,000, 125,000, 150,000, 175,000, 200,000, 250,000, 300,000, 350,000 and 400,000 BTU/h), which is an estimate of what is on the shelf: makers differ, so check the catalogue. 3) Heat-up time for a chosen heater: hours = heat to add ÷ (heater input × efficiency). A 250,000 BTU/h heater at 82% puts 205,000 BTU/h into the water and so takes 13 h 50 min for the default pool, in still, warm conditions. Efficiency: the federal minimum for a gas pool heater has been 82% thermal efficiency since 2013; DOE’s 2023 final rule moves to a new integrated thermal efficiency metric of about 84% with compliance from May 2028. Electric resistance is about 100%. Heat pumps are rated by their output and a coefficient of performance (COP), not by this efficiency, so size a heat pump by the output BTU/h shown as “into the water” and compare it with the maker’s heating capacity at your air temperature; heat pump capacity drops in cool air. Temperatures enter only as differences, so °C is converted with × 1.8 and °C and °F give the same answer for the same pool. The surface area is converted from square metres at 10.764 sq ft per square metre, and litres and imperial gallons are converted to US gallons first (3.785 L and 4.546 L per gallon respectively). What is not modelled: a pool cover or solar blanket (which lowers the heat loss a great deal in practice), a windbreak, indoor pools, spas, the heat gained from the sun, the time the pump runs, and altitude (a gas heater loses rating at altitude). A gas heater also needs the right gas supply line, venting and clearances: sizing is only part of the choice.
- U.S. Department of Energy, Energy Saver: Gas Pool Heaters. Rough sizing for an outdoor pool: desired water temperature minus the average air temperature of the coldest month of use gives the temperature rise; surface area (sq ft) × rise × 12 = BTU/h; the 12 assumes a 1 to 1 1/4 °F per hour warm-up and a 3 1/2 mph average wind, and the result is multiplied by 1.5 for a 1 1/2 °F rise per hour and by 2.0 for 2 °F. Wind, humidity and cool nights also affect the load, and a trained pool professional should do a proper analysis
- Pentair, Engineering Data Sheet 2025-2026 (copy hosted by the Orange County Health Care Agency): heater sizing and heat-up time = volume in gallons × 8.34 lb per gallon × temperature rise × 60 minutes ÷ (heater BTU/h input × heater efficiency)
- U.S. Department of Energy, Energy Conservation Standards for Consumer Pool Heaters, final rule (2023): new integrated thermal efficiency standards for gas pool heaters, about 84%, with compliance from May 2028
- Air-Conditioning, Heating, and Refrigeration Institute (AHRI), Pool Heaters: the current federal minimum thermal efficiency for gas-fired pool heaters is 82% (heaters made from April 2013)
- Hayward, Universal H-Series gas pool heaters (product pages and quick manual): inputs of 150,000, 200,000, 250,000, 300,000, 350,000 and 400,000 BTU/h. Used for the common-size list together with other makers’ catalogues, which were not each checked
- U.S. Department of Energy, Better Buildings Solution Center, Pool Efficiency: keeping a pool at the lower end of the recommended 78 to 82 °F range reduces energy costs
- Weight of water: 8.34 lb per US gallon (a US gallon is 231 cubic inches). One BTU is the heat to raise one pound of water one degree Fahrenheit; 1 kWh = 3,412.14 BTU
How to size a pool heater
- Find the volume and surface area. Use the volume from your pool’s papers or work it out with the pool volume calculator, and measure the area of the water surface (length × width for a rectangle).
- Set the temperatures. Enter the current water temperature, the temperature you want, and the average air temperature of the coldest month you plan to swim in.
- Choose the heat-up time and efficiency. Pick how many hours you are willing to wait and the heater’s nameplate efficiency (82% is the federal minimum for gas).
- Read the larger of the two sizes. The heater needs both the heat-up input and the DOE surface-area input; buy at or above the larger, at the next common size.
- Test a heater you are considering. Enter its input rating to see the heat-up time and whether it covers the surface-area load, then have a pool professional confirm the size, gas line and venting.
Worked examples
| Project | Result |
|---|---|
| 20,000 gallon, 500 sq ft pool, 65 to 82 °F in 24 hours, 82% gas heater | 161,000 BTU/h (heat-up 145,000 BTU/h, surface 161,000 BTU/h) |
| Same pool at the 1.5 °F per hour rate | 242,000 BTU/h |
| Same pool at the 2 °F per hour rate | 322,000 BTU/h |
| Same pool, electric resistance heater at 100% | 132,000 BTU/h |
| Same pool in 48 hours instead of 24 | 161,000 BTU/h |
| Same pool, 400,000 BTU/h heater: heat-up time | 161,000 BTU/h; heat-up takes about 8 h 39 min |
| Same pool, 100,000 BTU/h heater: heat-up time | 161,000 BTU/h; heat-up takes about 34 h 35 min |
| 10,000 gallon, 300 sq ft pool, 70 to 84 °F in 12 hours, air 65 °F | 119,000 BTU/h |
| 75,000 litre, 40 m² pool, 18 to 28 °C, air 16 °C | 152,000 BTU/h |
Frequently asked questions
- How do I calculate the BTU/h to heat a pool?
- Heat to add = gallons × 8.34 lb per gallon × the rise in °F, in BTU. Divide by the hours you are willing to wait for BTU/h into the water, then by the heater’s efficiency for the input rating. For 20,000 gallons rising 17 °F in 24 hours at 82% that is 145,000 BTU/h of input. A pool that must only warm by 10 °F in the same time needs 85,000 BTU/h.
- What is the DOE formula for sizing a pool heater?
- The U.S. Department of Energy’s Energy Saver page on gas pool heaters says to multiply the pool’s surface area in square feet by the difference between the desired water temperature and the average air temperature of the coldest month you will use the pool, then by 12, to get BTU/h. The 12 assumes the pool warms 1 to 1 1/4 °F an hour in a 3 1/2 mph wind; multiply by 1.5 for 1 1/2 °F an hour and by 2 for 2 °F. For 500 sq ft and a 22 °F difference that is 132,000 BTU/h, or 264,000 BTU/h at the 2 °F per hour rate. It is a rough method.
- Which answer do I buy: the heat-up size or the surface-area size?
- The larger one, because the heater has to do both jobs. A heater sized only on the surface-area load heats a cold pool slowly; one sized only on the heat-up time can fall short in the coldest weather. In the default example the heat-up needs 145,000 BTU/h and the surface-area method 161,000 BTU/h, so the second sets the size. Waiting 48 hours instead of 24 cuts the heat-up input to 73,000 BTU/h, but it does not change the surface-area input.
- How long will my heater take to warm the pool?
- Hours = gallons × 8.34 × rise ÷ (heater input × efficiency). The 20,000 gallon default pool, 17 °F, takes 13 h 50 min with a 250,000 BTU/h heater at 82%, 34 h 35 min with 100,000 BTU/h, and 8 h 39 min with 400,000 BTU/h. These ignore the heat the pool loses meanwhile, so a real heat-up is longer, most of all on a cool, windy night with no cover.
- Does heater efficiency matter?
- Yes: the nameplate input is bigger than the heat that reaches the water. A gas heater at 82% (the federal minimum) delivers 82 BTU of every 100 BTU of gas. The same heat-up at 100% needs 119,000 BTU/h instead of 145,000 BTU/h. For a heat pump, use its rated heating output at your air temperature rather than an efficiency: it is the output BTU/h that has to match the “into the water” figure.
- Can I use a smaller heater and just wait longer?
- Often yes, for an occasional swim: a smaller heater takes proportionally longer (half the size, twice the time). But a heater whose output is below the surface-area load cannot hold the temperature against the heat the pool loses in cold weather, however long you wait. A 100,000 BTU/h heater at 82% puts 82,000 BTU/h into the water; the default pool’s DOE load is 132,000 BTU/h.
- How much does wind or a faster warm-up change the size?
- The DOE factor of 12 assumes a warm-up of 1 to 1 1/4 °F an hour and a 3 1/2 mph average wind. Choosing the 1.5 °F per hour rate multiplies the surface-area load by 1.5 (242,000 BTU/h instead of 161,000 BTU/h for the default pool) and the 2 °F rate by 2 (322,000 BTU/h). A windy site, low humidity and cool nights push the load up too, which a rule of thumb cannot capture. Ask a pool professional for a heat-loss calculation.
- Does a pool cover let me use a smaller heater?
- In practice yes: most of a pool’s heat is lost from its surface, mainly by evaporation, so a cover or solar blanket cuts the load. The DOE surface-area figure is for an uncovered outdoor pool and this calculator has no cover setting, so treat its result as the upper end; with a cover that is used every night, a smaller heater, or the same one running for fewer hours, can do the job (an estimate, not a calculated saving).
- What if my pool is in litres, square metres or °C?
- Pick the units in the three unit fields and the calculator converts them to US gallons, square feet and °F differences (× 1.8) before it works. A 75,000 litre, 40 m² pool warmed from 18 to 28 °C with the coldest month averaging 16 °C needs 152,000 BTU/h of input (heat-up 152,000 BTU/h, surface-area 137,000 BTU/h); the 100,000 BTU/h heater you may be testing takes 36 h 16 min for that rise. In kilowatts, 1 kW is 3,412 BTU/h.
- What if the pool is already warmer than the target?
- Then the heat-up part is zero and the calculator says so: at 85 °F against an 82 °F target there is nothing to add. The surface-area load still applies if the air is colder than the target, because that is the heat needed to hold the temperature.
- Do propane and natural gas heaters need different sizes?
- No: the BTU/h input rating is the same for either fuel, because the heater is built for one or the other and its nameplate input is what you size. The fuel affects the supply line and the running cost. The propane usage calculator turns a heater’s BTU/h and its hours of running into gallons of propane.
- Is this an exact answer?
- No. The heat-up arithmetic is exact physics, but the pool’s heat loss is not: wind, humidity, cool nights, sun, a cover and the pump all change it, and the DOE surface-area figure is a rule of thumb for the DOE’s own assumptions. Use the suggested size as a starting point and have a pool professional confirm it, along with gas line, venting and clearances. A 119,000 BTU/h result for a 10,000 gallon pool shows how the size scales with the pool.