A 12 × 8 ft bed (96 sq ft) planted 18 in apart holds 40 plants, the same layout as the plant spacing calculator. With 2 emitters of 1 GPH on each plant that is 80 emitters putting out 80 GPH, or 1.33 GPM. One inch a week over the bed is 96 × 0.6234 = 59.8 gallons, and at a drip efficiency of 0.9 that is 66.5 gallons through the emitters, so the answer is 50 min of drip per week (66.5 ÷ 80 GPH = 0.83 hours). On 3 days that is about 17 min a day. The zone draws 1.33 GPM, well inside the 3.75 GPM usable from a spigot that tested at 5 GPM. A typical 1/2 in line carries up to 200 emitters of 1 GPH (200 GPH), and a 1/4 in line up to 30 (30 GPH).

Figures based on the sources listed belowUpdated How we calculate

From the bed it uses the same layout as the plant spacing calculator: a square grid with half the spacing kept clear of the edge. For a single row, make the width 1 ft or less.

Center to center, as on the plant tag.
One for small plants, two or more for shrubs, tomatoes and other big feeders, so the wetted soil reaches the roots on both sides.
Gallons per hour of each emitter, printed on the package. 0.5 GPH suits clay; 1 or 2 GPH suit loam and sand. For inline emitter tubing, use the flow of one emitter and count the emitters.
About 1 inch a week over the bed is the usual starting point for vegetables in summer; shrubs and trees are often watered by gallons per plant instead.

Inches over the bed area, rain included: take off any rain that soaked in. 1 in over 1 sq ft is 0.623 gallons.
Drip is often cited at 90% or better, against 50 to 70% for sprinklers, so the run time is divided by 0.9. Leaks, clogged emitters and runoff on slopes lower it.
Fewer, deeper waterings grow deeper roots. Sandy soil does better on more days with shorter runs; follow any watering-day limits where you live.

Time how long the spigot takes to fill a 5 gallon bucket with the hose and nothing else running, then GPM = 300 ÷ seconds (47 s is 6.4 GPM). Repeat three times and average.
The bucket test is an open spigot. A filter, a pressure regulator, a timer and a long hose all take some of it, so the zone should draw less than the test. 75% is an estimate, not a rule.

The distance from the connection to the far end of the longest line of 1/2 in tubing. Typical advice is to stay under 200 ft.

50 min of drip per week.

50 min of drip per week

  • Run time per week: 50 min (0.8 h)
  • Run time per watering day: 17 min, 3 days a week
  • Zone flow: 80 GPH (1.33 GPM)
  • Emitters on the zone: 80 (40 plants x 2)
  • Water through the emitters per week: 66.5 gal
  • Application rate over the bed: 1.34 in/h (34 mm/h)
  • Supply check (bucket test): Fits: the zone draws 1.33 GPM of the 3.75 GPM usable (5 GPM tested)
  • 1/2 in tubing (typical): up to 200 emitters of 1 GPH (200 GPH, 200 ft per run); this zone's 80 emitters need 1 run on flow
  • 1/4 in tubing (typical): up to 30 emitters of 1 GPH (30 GPH, 30 ft per run); 2 per plant fits on one line
  • Longest 1/2 in run (typical limit 200 ft): 100 ft is within 200 ft

Shopping list

  • Drip irrigation kit for raised beds
  • Pressure regulator and filter for drip (25 psi)
  • 1/2 in poly drip tubing (.600 ID)
  • Adjustable and fixed drip emitters
  • Hose-end timer
  • 5 gallon bucket for a flow test
Show diagram

Saved projects

No saved projects yet.

Typical tubing limits and the most emitters on one run

Typical design rules, an estimate: emitters = the GPH limit ÷ the emitter flow, rounded down. Check the data sheet of your tubing; dripline has its own maximum run chart.
TubingMax runMax flow0.5 GPH emitters1 GPH emitters2 GPH emitters
1/2 in (0.600 in inside diameter), typical200 ft200 GPH400200100
1/4 in, typical30 ft30 GPH603015
1/2 in (0.700 in outside diameter), DIG ceiling350 ft (safe single run)220 GPH (3.6 GPM)440220110

Zone flow by number of emitters

Emitters × emitter flow, in GPM and GPH. Compare it with your supply flow from the bucket test.
Emitters0.5 GPH each1 GPH each2 GPH each
20 emitters0.17 GPM (10 GPH)0.33 GPM (20 GPH)0.67 GPM (40 GPH)
40 emitters0.33 GPM (20 GPH)0.67 GPM (40 GPH)1.33 GPM (80 GPH)
80 emitters0.67 GPM (40 GPH)1.33 GPM (80 GPH)2.67 GPM (160 GPH)
100 emitters0.83 GPM (50 GPH)1.67 GPM (100 GPH)3.33 GPM (200 GPH)
200 emitters1.67 GPM (100 GPH)3.33 GPM (200 GPH)6.67 GPM (400 GPH)

Water and run time for 1 inch a week by bed size

Each inch on each sq ft is 0.6234 gal; through emitters at efficiency 0.9. Minutes per week at a zone flow of 1, 2 or 4 GPM (60, 120 or 240 GPH). Worked by this calculator's formulas at build time.
Bed areaPlants needThrough emittersAt 1 GPMAt 2 GPMAt 4 GPM
25 sq ft15.6 gal17.3 gal17 min9 min4 min
50 sq ft31.2 gal34.6 gal35 min17 min9 min
100 sq ft62.3 gal69.3 gal69 min35 min17 min
200 sq ft124.7 gal138.5 gal139 min69 min35 min
400 sq ft249.4 gal277.1 gal277 min139 min69 min

Bucket test: seconds to fill 5 gallons

GPM = 300 ÷ seconds. Usable is 75% of the tested flow (an estimate); the last two columns are the most emitters of 1 or 2 GPH that usable flow runs.
Fill timeTested flowUsable (75%)Emitters at 1 GPHEmitters at 2 GPH
20 s15 GPM11.25 GPM6751,350
30 s10 GPM7.5 GPM450900
45 s6.67 GPM5 GPM300600
60 s5 GPM3.75 GPM225450
90 s3.33 GPM2.5 GPM150300
120 s2.5 GPM1.88 GPM113225

Methodology & assumptions

Plants. By default the calculator lays the bed out with the plant spacing calculator's own logic: a square grid, rows along the length, half the spacing kept clear of every edge, and plants = (floor of usable length ÷ spacing + 1) × (floor of usable width ÷ spacing + 1); areas you mark as not planted scale the count by their share. If you already know how many plants are on the zone, choose the entered count instead. For a single row, make the bed 1 ft wide or less. Zone flow. Emitters = plants × emitters per plant, and zone flow in GPH = emitters × the flow of one emitter (0.5, 1 or 2 GPH, the common fixed sizes); GPM = GPH ÷ 60. Inline emitter tubing counts the same way: one emitter per emitter, at its own flow. Water to apply. By depth, the weekly need is area × inches × 0.6234 gallons, the same 144 ÷ 231 constant the sprinkler run time calculator uses; by plant, it is plants × gallons per plant. About 1 inch a week over the bed (0.623 gallons per sq ft) is the usual extension starting point for vegetables in summer, and about half that in cool spring or fall weather; hot, dry or windy weather can need more, and trees and shrubs are better planned by gallons per plant. Efficiency. Drip puts water at the roots with little evaporation or runoff, and extension sources quote efficiencies of 90% or better, against 50 to 70% for sprinklers; the run time divides by 0.9 (an estimate), so 10% more water goes through the emitters than the plants take up. This is not the sprinkler calculator's distribution uniformity of 0.55 to 0.75, because drip has no overlapping spray pattern to even out; a leaking or clogged system scores lower, so the 0.8 setting is there. Run time. Minutes per week = gallons through the emitters ÷ zone GPH × 60, split over the watering days you choose. The application rate over the bed is 1.604 × zone GPH ÷ area in inches per hour; 1.604 is 96.25 ÷ 60, the sprinkler calculator's constant per minute, and Utah State Extension uses the same number. Drip applies at a point, so water spreads sideways and down in the soil and the rate over the bed is an average, not what the soil surface takes in. Sandy soils spread water less sideways, so they want closer emitters or more of them; clay takes it in slowly, so 0.5 GPH emitters and shorter, more frequent runs suit it. Tubing limits. The limits shown are typical design rules, stated as estimates: 1/2 in polyethylene tubing (0.600 in inside diameter) up to 200 ft and 200 GPH in one run, which keeps the water at about 5 ft per second, and 1/4 in tubing up to 30 ft and 30 GPH. The maximum number of emitters is the GPH limit ÷ the emitter flow, rounded down: 400, 200 or 100 emitters (0.5, 1 or 2 GPH) on a 1/2 in run and 60, 30 or 15 on a 1/4 in line. Manufacturers publish higher ceilings for some tubing: DIG gives 220 GPH (3.6 GPM) and about 350 ft as a safe single run for 0.700 in outside diameter tubing at 20 to 40 psi, and a retailer gives 240 GPH for 1/2 in mainline, so stay with the lower rule unless your tubing's data sheet allows more. Inline emitter tubing (dripline) is different: its maximum run depends on the emitter spacing, the emitter flow and the inlet pressure, so use the maker's chart for the exact product (Netafim and Toro publish them) and keep to the pressure range on the label, usually 10 to 60 psi, with a regulator at 25 to 30 psi for most drip fittings. Supply check. Time a 5 gallon bucket at the spigot: GPM = 300 ÷ seconds. The zone's GPM is compared with the usable share of the tested flow (75% by default, an estimate, to leave room for the pressure lost in the filter, regulator, timer and hose); if the zone is over, it is split into the number of zones the supply can run one at a time, ceil(zone GPM ÷ usable GPM). Not modelled: pressure and friction loss along the line (a hydraulic design needs the pipe diameter, length and fittings), elevation change, emitter clogging, rain, ET, soil water holding capacity and root depth, and watering restrictions. Metric: lengths and depths follow the switch, flow stays in GPH and GPM next to the litre amounts.

How to size a drip irrigation zone

  1. Count the plants. Enter the bed length and width and the plant spacing, or enter the number of plants if you know it.
  2. Choose the emitters. Pick how many emitters each plant gets and the flow of each (0.5, 1 or 2 GPH), then read the zone flow in GPH and GPM.
  3. Set the weekly water. Use about 1 inch a week over the bed for vegetables, or gallons per plant for shrubs, and keep the 0.9 efficiency allowance.
  4. Read the run time. The weekly minutes are the gallons through the emitters divided by the zone GPH; split them over your watering days.
  5. Check the tubing and the supply. Keep each 1/2 in run under about 200 ft and 200 GPH and each 1/4 in line under 30 ft and 30 GPH, and compare the zone GPM with the usable share of your bucket-test flow, splitting the bed into zones if it is over.

Worked examples

ProjectResult
12 × 8 ft bed at 18 in, 2 emitters of 1 GPH per plant, 1 in a week, 3 days, 5 GPM supply50 min of drip per week: 40 plants, 80 GPH (1.33 GPM), 17 min a day, about 66 gal
20 ft row of 10 tomatoes, 2 emitters of 2 GPH each, 10 gallons per plant a week, 3 days167 min of drip per week: 40 GPH (0.67 GPM), 56 min a day, about 111 gal
25 ft row of lettuce at 12 in, one 0.5 GPH emitter each (clay), 1 in a week, 2 days83 min of drip per week: 25 plants, 12.5 GPH (0.21 GPM), 42 min a day, about 17 gal
30 × 10 ft bed at 18 in, 2 emitters of 2 GPH per plant, 5 GPM supply at 75%26 min of drip per week: 120 plants, 480 GPH (8 GPM), over the 3.75 GPM usable, so 3 zones

Frequently asked questions

How do I calculate the flow of a drip zone?
Multiply the number of emitters by the flow of each one. The example bed has 40 plants with 2 emitters of 1 GPH each, so 80 × 1 = 80 GPH, which is 80 ÷ 60 = 1.33 GPM. That figure must fit inside what your spigot can supply and what the tubing can carry.
How long should I run drip irrigation?
Gallons needed ÷ zone GPH. One inch a week on the 96 sq ft example bed is 59.8 gallons, 66.5 with the 0.9 efficiency allowance, and the zone delivers 80 GPH, so about 50 min a week. Spread over 3 days that is 17 min each day. If you plan by plant instead, 10 tomato plants at 10 gallons each on 2 emitters of 2 GPH run 167 min a week.
How many emitters can I put on 1/2 inch tubing?
The usual rule is no more than 200 GPH and 200 ft on a run of 1/2 in tubing, which is 400 emitters of 0.5 GPH, 200 of 1 GPH or 100 of 2 GPH. DIG gives a higher ceiling of 220 GPH for 0.700 in OD tubing, and some retailers quote 240 GPH, so 200 is the cautious figure. These are typical limits; past them the emitters at the far end get less water.
How many emitters can I put on 1/4 inch tubing?
The common rule for 1/4 in tubing is 30 ft and 30 GPH, which is 60 emitters of 0.5 GPH, 30 of 1 GPH or 15 of 2 GPH. In practice 1/4 in line is used for short branches from the 1/2 in line to individual plants, with one to four emitters on each, which is far below the limit.
How do I know if my faucet can run the zone?
Do a bucket test: time how long the spigot takes to fill a 5 gallon bucket with nothing else running, and divide 300 by the seconds (47 seconds is 6.4 GPM). Enter that flow. The calculator uses 75% of it as usable, because the filter, regulator, timer and hose take some of it, and compares it with the zone. A bed that is over is split into zones that run one after another: the 30 × 10 ft example with 2 GPH emitters draws 8 GPM against 3.75 usable, so it needs 3 zones.
Which emitter flow should I use: 0.5, 1 or 2 GPH?
Slower emitters suit clay, which takes in water slowly and puddles under fast ones. 1 or 2 GPH suits loam and sand, where water moves down quickly and needs to spread sideways. For the same weekly gallons, a 2 GPH emitter runs a quarter of the time of a 0.5 GPH one and draws four times the flow: the 25 ft lettuce row at 0.5 GPH needs 83 min a week on 25 emitters, with a zone flow of only 0.21 GPM.
Why is drip efficiency 0.9 and not the DU the sprinkler calculator uses?
Sprinklers throw water over the whole area and the overlap is uneven, so the driest spots set the run time and the sprinkler calculator divides by a distribution uniformity of about 0.55 to 0.75. Drip puts the water at the plant, so extension sources quote efficiencies of 90% or better, against 50 to 70% for sprinklers. The 0.9 is a typical figure; pick 0.8 for an old or leaking system.
How much water do garden beds need per week?
About 1 inch over the bed per week is the usual start for vegetables in summer, which is 0.623 gallons per sq ft, and about half that in cool spring or fall weather. Hot, dry or windy weather can need more, and your own soil, plant size and rain change it. Take off rain that soaked in, or choose gallons per plant for shrubs and trees.
What application rate does drip give?
Zone GPH × 1.604 ÷ area, in inches per hour. The example puts 80 GPH over 96 sq ft: 80 × 1.6 ÷ 96 = 1.34 in/h. That is an average over the whole bed; the water really goes in at the emitters and spreads through the soil from there, so the rate under an emitter is far higher than the average and the soil, not this figure, sets how fast an emitter can run without puddling.
Can I rain-barrel water for drip irrigation?
Yes, but a barrel on the ground gives very little pressure, so most drip fittings and emitters need a small pump or a barrel raised high, and pressure-compensating emitters have a minimum working pressure printed on the package. Use the rainwater harvesting calculator to see how many gallons a roof collects against the weekly gallons here.

Handy tools

  • Unit Converter: Switch between gallons per hour and per minute, gallons and litres, or inches and millimetres.
  • Feet and Inches Calculator: Add up bed sides and tubing runs measured in feet, inches and fractions, and get decimal feet for the fields.

Related calculators