A house with 80 ft of eave and 36 ft of boxed rake (a 40 × 30 ft gable house) with a 16 in eave overhang and a 12 in rake overhang needs 14 panels of 12 in × 12 ft vinyl soffit with 10% extra for cuts, covering 143 sq ft. Each 12 ft panel is cut into 9 pieces 16 in long, so it covers 9 ft of eave. It also needs 21 lengths of J-channel or F-channel for the wall and fascia sides and 2 coils of aluminum trim coil for 116 ft of 6 in fascia. All-vented panels rated 5.3 sq in per ft give 424 sq in of intake, short of the 576 sq in the attic ventilation calculator asks for on a 1,200 sq ft attic at 1/150.

Figures based on the sources listed belowUpdated How we calculate

Extra for cuts and corners
Vinyl soffit is commonly sold as 12 in wide by 12 ft panels (Triple 4 and Double 5 profiles), aluminum as 16 in by 12 ft, and plywood as 4 × 8 ft sheets. Panels run from the wall to the fascia and are cut to the overhang. Check the width and length of the panel you buy.

From the wall to the fascia, measured flat. Typical overhangs are 12 to 24 in. A deeper overhang wastes more of a 12 ft panel in offcuts.

Used only for boxed rakes (the total rake length above). Open rakes have no soffit.

The visible face of the fascia, from the roof edge down to the soffit. A 1 × 6 board is 5.5 in tall, a 1 × 8 is 7.25 in. It sets the board size and how many strips a coil yields.
Trim coil is bent on site to wrap the fascia: it is cut into strips the face height plus about 2.5 in wide (an estimate for the tuck under the drip edge and the bottom hem). Boards are counted by length only; lumber yards stock 1-by boards in several lengths.
Vented panels are perforated or slotted to let air into the attic. Mixing vented and solid panels is common. Only eave soffit counts as intake; a boxed rake gives no air path.

Net free area per lineal foot of soffit as printed on the product. Published figures vary: Alside D5 punched vinyl soffit is 5.3, a Triple 4 perforated vinyl panel 5.89, a Triple 4 lanced panel 7.2, and a 16 in aluminum vented panel 6.48. The attic ventilation calculator uses 9 for a continuous aluminum soffit vent strip. Use your product’s number.

The vented attic floor area, as in the attic ventilation calculator (40 × 30 ft is 1,200 sq ft). Enter 0 to skip the intake check.
IRC R806.2 sets 1 sq ft of net free area per 150 sq ft of attic floor. It allows 1/300 only where the exception is met: a Class I or II vapor retarder on the warm side of the ceiling in climate zones 6 to 8, and 40 to 50% of the area high (within 3 ft of the ridge), with the rest at the eaves. The wording differs by edition, so check the one your area adopted. When in doubt use 1/150.
The code exception wants 40 to 50% of the area high, so exhaust never goes above half. Favouring intake keeps the attic from pulling conditioned air through the ceiling. These are the only splits offered.

Buy 14 panels.

Buy 14 panels

142.67 sq ft + 10% waste = 156.93 sq ft

  • Soffit area: 143 sq ft
  • J-channel or F-channel (12.5 ft pieces, wall and fascia sides): 21 pieces (about 255.2 ft)
  • Fascia coil (24 in × 50 ft): 2 coils (cut 2 strips per coil)
  • Intake NFA from the vented soffit: 424 sq in (2.94 sq ft)
  • Intake NFA the attic needs (attic ventilation rule): 576 sq in (4 sq ft)
  • Intake check: Short by 152 sq in (1.06 sq ft), 109 ft of vented soffit at 5.3 sq in per ft would cover it
How this number is calculated

142.67 sq ft + 10% waste = 156.93 sq ft ÷ 12 sq ft per panel = 14 panels

Shopping list

  • Vinyl soffit panels (vented)
  • Aluminum soffit panels (vented)
  • J-channel
  • F-channel for soffit
  • Aluminum trim coil (24 in)
  • Aluminum nails or trim nails
  • Tin snips (aviation snips)
Show diagram

Saved projects

No saved projects yet.

12 in × 12 ft vinyl soffit panels by eave length and overhang

Plain eaves with no rakes, 10% extra, panels run wall to fascia. Overhang is measured from the wall to the fascia. Worked by this calculator.
Eave length12 in overhang16 in overhang18 in overhang24 in overhang
40 ft4568
60 ft68911
80 ft8101115
100 ft10131419
120 ft11151722
160 ft15202230

16 in × 12 ft aluminum soffit panels by eave length and overhang

Plain eaves with no rakes, 10% extra. A 16 in wide piece covers 16 in of eave. Worked by this calculator.
Eave length12 in overhang16 in overhang18 in overhang24 in overhang
40 ft3456
60 ft5679
80 ft68911
100 ft7101114
120 ft9111317
160 ft11151722

Eave covered by one panel, by overhang

A 12 ft panel is cut to the overhang; the remainder is waste. Plywood is the better of ripping strips along the sheet or cutting across it.
OverhangPieces per 12 ft panelVinyl 12 in panel coversAluminum 16 in panel coversPlywood 4 × 8 sheet covers
12 in1212 ft16 ft32 ft
16 in99 ft12 ft24 ft
18 in88 ft10.7 ft20 ft
20 in77 ft9.3 ft16 ft
24 in66 ft8 ft16 ft
30 in44 ft5.3 ft12 ft

Intake NFA needed by attic size, and vented soffit to supply it

The 1/150 base rule with half the ventilation as intake, from the attic ventilation calculator’s formula. Feet of vented soffit at 5.3 sq in per ft (Alside D5 punched vinyl) and at 9 sq in per ft (a continuous aluminum soffit vent strip). Many attics also need other intake to reach it.
Attic floor areaIntake NFA needed (sq in)Vented soffit at 5.3 sq in per ftVented soffit at 9 sq in per ft
800 sq ft38473 ft43 ft
1,200 sq ft576109 ft64 ft
1,600 sq ft768145 ft86 ft
2,000 sq ft960182 ft107 ft
2,400 sq ft1,152218 ft128 ft

Published net free area of vented soffit panels

NFA per lineal foot as listed by each seller or maker (see Sources). Panels with the same profile differ by hole pattern: use the figure for your product.
PanelNet free area per ft
Alside D5 punched vinyl soffit, 12 ft5.3 sq in
Triple 4 vinyl, perforated full vent, 12 ft × 12 in (Mitten)5.89 sq in
Triple 4 vinyl, lanced full vent, 12 ft × 12 in (Mitten)7.2 sq in
Kent Double 5 perforated vinyl4.2 sq in
Sell Even vented aluminum, 16 in × 12 ft (Menards)6.48 sq in
Air Vent SV201 continuous aluminum soffit vent9 sq in

Methodology & assumptions

The soffit is a strip as deep as the overhang along every eave, and along every rake you will box in; the area on this page is that strip, less any section you leave out. The panel count is worked in pieces, not by area, because a panel runs from the wall to the fascia and is cut to the overhang depth, and the offcut is mostly lost. A 12 ft (144 in) vinyl or aluminum panel gives floor(144 ÷ overhang) pieces; each piece covers the panel’s width of the eave (12 in for vinyl, 16 in for aluminum), so one panel covers floor(144 ÷ overhang) × width of run. For plywood 4 × 8 ft sheets the calculator takes the better of ripping strips the overhang wide along the 8 ft (floor(48 ÷ overhang) strips, each 8 ft long) and cutting across (floor(96 ÷ overhang) pieces, each 4 ft wide). Panels = (eave run ÷ run per panel, plus rake run ÷ run per panel at the rake depth) × (1 + extra), rounded up. The panel widths used are the nominal ones; the real coverage of an interlocking panel is a little less than its nominal width, which the extra absorbs. The cut length is taken as the overhang depth: installers subtract a small expansion gap (CertainTeed’s installation guide says to subtract 1/2 in from the wall-to-fascia measurement, others 1/4 in) but the panel also sits into the channel at each end, so the two roughly cancel; this is an estimate, so check your panel’s instructions. Channel is counted on both sides of every run (a channel at the wall and one at the fascia), in 12.5 ft lengths for vinyl and 12 ft for aluminum, with the same extra added. Plywood needs no channel. Fascia is the eave and rake length together. Trim coil is cut into strips the fascia height plus about 2.5 in wide (an estimate for the tuck under the drip edge and the bottom hem), and 24 in ÷ that, rounded down, strips come from each 50 ft coil. Boards are counted by length only, in 12 ft or 16 ft pieces, and the size shown is the narrowest 1-by board at least as tall as the face. For vented soffit the intake net free area (NFA) provided is the eave length × the share vented × the NFA per ft you enter. The area needed is the attic ventilation calculator’s own rule: attic floor area ÷ 150 (or 300 where the code exception applies) × 144, with the intake share you pick (50, 55 or 60%), so the two pages never disagree; the line under the result says whether the soffit covers it or how many sq in or feet of vented soffit are missing. Only eave soffit counts: a boxed rake is not an air path into the attic. Nails, screws, lookouts, nailing strips and sealant are not counted. The metric toggle shows lengths in m; panel sizes and NFA stay in inches because that is how products are sold.

How to calculate soffit and fascia materials

  1. Measure the eaves and rakes. Add up the eave length. Add the rake length too only if you will box the rakes.
  2. Measure the overhang. Measure from the wall to the fascia. Note the height of the fascia face.
  3. Pick the material. Vinyl 12 in × 12 ft, aluminum 16 in × 12 ft or plywood 4 × 8 ft sheets. The calculator counts the pieces each panel gives at your overhang.
  4. Add the channel and fascia. Channel at the wall and the fascia, so twice the run, in 12 ft to 12.5 ft pieces; fascia coil or boards over the eave and rake length.
  5. Check the vent area. If the soffit is vented, enter the panel’s NFA per foot and the attic floor area to compare the intake with the attic ventilation rule.

Worked examples

ProjectResult
40 × 30 ft gable house: 80 ft of eave at 16 in, 36 ft of boxed rake at 12 in, vinyl, 10% extra, aluminum coil fascia14 panels (143 sq ft of soffit), 21 lengths of channel, 2 coils of fascia coil
100 ft of eave, no rakes, 12 in overhang, aluminum 16 in panels, 5% extra, 1 × 8 fascia boards in 16 ft lengths7 panels (100 sq ft of soffit), 18 lengths of channel, 7 fascia boards
60 ft of eave, no rakes, 24 in overhang, plywood 4 × 8 ft sheets, solid soffit, 10% extra5 panels (120 sq ft of soffit), no channel, 1 coil of fascia coil

Frequently asked questions

How many soffit panels do I need?
Work out how many pieces one panel gives, then divide. A 12 ft vinyl panel cut to a 16 in overhang gives 9 pieces, each 12 in wide, so it covers 9 ft of eave. 80 ft of eave and 36 ft of boxed rake (rake at a 12 in overhang, 12 ft per panel) is 80 ÷ 9 + 36 ÷ 12 = 11.9 panels; with 10% extra that is 14. The calculator does this for any overhang and material.
What size are soffit panels?
Vinyl soffit is commonly sold as 12 in wide panels 12 ft long (Triple 4 and Double 5 profiles), aluminum soffit as 16 in by 12 ft panels, and plywood as 4 × 8 ft sheets. Other widths and lengths exist, so check the panel you buy: the calculator assumes the nominal sizes.
How much J-channel or F-channel do I need?
Vinyl and aluminum soffit sits in a channel at the wall and another at the fascia, so you need the run length twice. F-channel, J-channel and similar receiving channel come in 12 ft (aluminum) and 12 ft 6 in (vinyl) lengths. The example with 116 ft of eave and rake needs 21 lengths with 10% extra. Plywood soffit needs no channel.
How do I work out fascia coil or boards?
Fascia length is the eave plus the rake. Aluminum trim coil comes in 24 in wide, 50 ft rolls and is cut into strips about 2.5 in wider than the fascia face, so a 6 in face gives 2 strips and a coil covers 100 ft. Boards are counted in 12 ft or 16 ft pieces. The calculator shows both ways.
How much net free area does vented soffit have?
It depends on the product: published figures run from about 4.2 to 7.2 sq in per lineal foot for vented vinyl (Alside D5 punched is 5.3), about 6.5 sq in per foot for one 16 in aluminum vented panel, and 9 sq in per foot for a continuous aluminum vent strip. Use the number printed on your panel; the NFA field takes it.
Is the soffit venting enough for my attic?
The calculator uses the same rule as the attic ventilation calculator: 1 sq ft of net free area per 150 sq ft of attic floor (1/300 where the code exception applies), split between intake at the eaves and exhaust high up. For a 1,200 sq ft attic at 1/150 and a 50/50 split that is 576 sq in of intake. 80 ft of all-vented panels at 5.3 sq in per ft supply 424 sq in, so you would add vented soffit elsewhere, use a higher-rated panel, or add other intake. With half the soffit vented it is 212 sq in. Code wording differs by edition, so confirm with your building department.
Do rake soffits count as ventilation?
No. A boxed rake closes the overhang along the gable end and does not open into the attic’s eave cavity, so only the eave soffit counts toward intake. The calculator counts rake soffit for panels and fascia only.
Can I use plywood for soffit?
Yes. APA says exterior panels should be used for a closed soffit, and a sanded or textured exterior face with paint holds up best. At a 24 in overhang the calculator gets 5 sheets for 60 ft of eave with 10% extra, because 4 × 8 sheets rip into 2 strips of 24 in. Plywood soffit has no vents of its own: cut vent openings or add vent strips if the attic needs intake.
Does this count nails, nailing strips and lookouts?
No. Nails or screws, nailing strips for wide overhangs, lookouts and sealant vary by job and installer, and no published coverage figure supports a count. Add them to your order from your product’s instructions.