Soffit and Fascia Calculator: How Many Soffit Panels?
A house with 80 ft of eave and 36 ft of boxed rake (a 40 × 30 ft gable house) with a 16 in eave overhang and a 12 in rake overhang needs 14 panels of 12 in × 12 ft vinyl soffit with 10% extra for cuts, covering 143 sq ft. Each 12 ft panel is cut into 9 pieces 16 in long, so it covers 9 ft of eave. It also needs 21 lengths of J-channel or F-channel for the wall and fascia sides and 2 coils of aluminum trim coil for 116 ft of 6 in fascia. All-vented panels rated 5.3 sq in per ft give 424 sq in of intake, short of the 576 sq in the attic ventilation calculator asks for on a 1,200 sq ft attic at 1/150.
Figures based on the sources listed belowUpdated How we calculate
Buy 14 panels.
Buy 14 panels
142.67 sq ft + 10% waste = 156.93 sq ft
- Soffit area: 143 sq ft
- J-channel or F-channel (12.5 ft pieces, wall and fascia sides): 21 pieces (about 255.2 ft)
- Fascia coil (24 in × 50 ft): 2 coils (cut 2 strips per coil)
- Intake NFA from the vented soffit: 424 sq in (2.94 sq ft)
- Intake NFA the attic needs (attic ventilation rule): 576 sq in (4 sq ft)
- Intake check: Short by 152 sq in (1.06 sq ft), 109 ft of vented soffit at 5.3 sq in per ft would cover it
How this number is calculated
142.67 sq ft + 10% waste = 156.93 sq ft ÷ 12 sq ft per panel = 14 panels
Shopping list
- Vinyl soffit panels (vented)
- Aluminum soffit panels (vented)
- J-channel
- F-channel for soffit
- Aluminum trim coil (24 in)
- Aluminum nails or trim nails
- Tin snips (aviation snips)
Your project
- Total eave length × total boxed rake length (0 if open): 80 × 36 ft
- Soffit material: Vinyl soffit, 12 in × 12 ft panels
- Eave overhang depth: 16 in
- Rake overhang depth: 12 in
- Fascia board height: 6 in
- Fascia covering: Aluminum trim coil over wood, 24 in × 50 ft
- Soffit that is vented: All of the eave soffit vented
- Vented panel NFA: 5.3 sq in per ft
- Attic floor area to ventilate: 1,200 sq ft
- Ventilation ratio: 1/150 of the attic floor area (base rule)
- Intake / exhaust split: Balanced: 50% intake, 50% exhaust
- Waste: Typical: cuts, mitres and mistakes (10%)
Also pick up
- Vinyl soffit panels (vented)
- Aluminum soffit panels (vented)
- J-channel
- F-channel for soffit
- Aluminum trim coil (24 in)
- Aluminum nails or trim nails
- Tin snips (aviation snips)
Reopen this calculation: /calculators/soffit/?s=eyJyb29tIjp7Imxlbmd0aEZ0Ijo4MCwid2lkdGhGdCI6MzZ9LCJkZWR1Y3Rpb25zIjpbXSwid2FzdGVQY3QiOjAuMSwicGFyYW1zIjp7InBhbmVsVHlwZSI6MSwib3ZlcmhhbmdJbiI6MTYsInJha2VPdmVyaGFuZ0luIjoxMiwiZmFzY2lhSGVpZ2h0SW4iOjYsImZhc2NpYU1hdGVyaWFsIjoxLCJ2ZW50ZWRQY3QiOjEwMCwibmZhUGVyRnQiOjUuMywiYXR0aWNBcmVhU3FGdCI6MTIwMCwicmF0aW9EZW5vbWluYXRvciI6MTUwLCJleGhhdXN0UGN0Ijo1MH19
Show diagram
Saved projects
No saved projects yet.
12 in × 12 ft vinyl soffit panels by eave length and overhang
| Eave length | 12 in overhang | 16 in overhang | 18 in overhang | 24 in overhang |
|---|---|---|---|---|
| 40 ft | 4 | 5 | 6 | 8 |
| 60 ft | 6 | 8 | 9 | 11 |
| 80 ft | 8 | 10 | 11 | 15 |
| 100 ft | 10 | 13 | 14 | 19 |
| 120 ft | 11 | 15 | 17 | 22 |
| 160 ft | 15 | 20 | 22 | 30 |
16 in × 12 ft aluminum soffit panels by eave length and overhang
| Eave length | 12 in overhang | 16 in overhang | 18 in overhang | 24 in overhang |
|---|---|---|---|---|
| 40 ft | 3 | 4 | 5 | 6 |
| 60 ft | 5 | 6 | 7 | 9 |
| 80 ft | 6 | 8 | 9 | 11 |
| 100 ft | 7 | 10 | 11 | 14 |
| 120 ft | 9 | 11 | 13 | 17 |
| 160 ft | 11 | 15 | 17 | 22 |
Eave covered by one panel, by overhang
| Overhang | Pieces per 12 ft panel | Vinyl 12 in panel covers | Aluminum 16 in panel covers | Plywood 4 × 8 sheet covers |
|---|---|---|---|---|
| 12 in | 12 | 12 ft | 16 ft | 32 ft |
| 16 in | 9 | 9 ft | 12 ft | 24 ft |
| 18 in | 8 | 8 ft | 10.7 ft | 20 ft |
| 20 in | 7 | 7 ft | 9.3 ft | 16 ft |
| 24 in | 6 | 6 ft | 8 ft | 16 ft |
| 30 in | 4 | 4 ft | 5.3 ft | 12 ft |
Intake NFA needed by attic size, and vented soffit to supply it
| Attic floor area | Intake NFA needed (sq in) | Vented soffit at 5.3 sq in per ft | Vented soffit at 9 sq in per ft |
|---|---|---|---|
| 800 sq ft | 384 | 73 ft | 43 ft |
| 1,200 sq ft | 576 | 109 ft | 64 ft |
| 1,600 sq ft | 768 | 145 ft | 86 ft |
| 2,000 sq ft | 960 | 182 ft | 107 ft |
| 2,400 sq ft | 1,152 | 218 ft | 128 ft |
Published net free area of vented soffit panels
| Panel | Net free area per ft |
|---|---|
| Alside D5 punched vinyl soffit, 12 ft | 5.3 sq in |
| Triple 4 vinyl, perforated full vent, 12 ft × 12 in (Mitten) | 5.89 sq in |
| Triple 4 vinyl, lanced full vent, 12 ft × 12 in (Mitten) | 7.2 sq in |
| Kent Double 5 perforated vinyl | 4.2 sq in |
| Sell Even vented aluminum, 16 in × 12 ft (Menards) | 6.48 sq in |
| Air Vent SV201 continuous aluminum soffit vent | 9 sq in |
Methodology & assumptions
The soffit is a strip as deep as the overhang along every eave, and along every rake you will box in; the area on this page is that strip, less any section you leave out. The panel count is worked in pieces, not by area, because a panel runs from the wall to the fascia and is cut to the overhang depth, and the offcut is mostly lost. A 12 ft (144 in) vinyl or aluminum panel gives floor(144 ÷ overhang) pieces; each piece covers the panel’s width of the eave (12 in for vinyl, 16 in for aluminum), so one panel covers floor(144 ÷ overhang) × width of run. For plywood 4 × 8 ft sheets the calculator takes the better of ripping strips the overhang wide along the 8 ft (floor(48 ÷ overhang) strips, each 8 ft long) and cutting across (floor(96 ÷ overhang) pieces, each 4 ft wide). Panels = (eave run ÷ run per panel, plus rake run ÷ run per panel at the rake depth) × (1 + extra), rounded up. The panel widths used are the nominal ones; the real coverage of an interlocking panel is a little less than its nominal width, which the extra absorbs. The cut length is taken as the overhang depth: installers subtract a small expansion gap (CertainTeed’s installation guide says to subtract 1/2 in from the wall-to-fascia measurement, others 1/4 in) but the panel also sits into the channel at each end, so the two roughly cancel; this is an estimate, so check your panel’s instructions. Channel is counted on both sides of every run (a channel at the wall and one at the fascia), in 12.5 ft lengths for vinyl and 12 ft for aluminum, with the same extra added. Plywood needs no channel. Fascia is the eave and rake length together. Trim coil is cut into strips the fascia height plus about 2.5 in wide (an estimate for the tuck under the drip edge and the bottom hem), and 24 in ÷ that, rounded down, strips come from each 50 ft coil. Boards are counted by length only, in 12 ft or 16 ft pieces, and the size shown is the narrowest 1-by board at least as tall as the face. For vented soffit the intake net free area (NFA) provided is the eave length × the share vented × the NFA per ft you enter. The area needed is the attic ventilation calculator’s own rule: attic floor area ÷ 150 (or 300 where the code exception applies) × 144, with the intake share you pick (50, 55 or 60%), so the two pages never disagree; the line under the result says whether the soffit covers it or how many sq in or feet of vented soffit are missing. Only eave soffit counts: a boxed rake is not an air path into the attic. Nails, screws, lookouts, nailing strips and sealant are not counted. The metric toggle shows lengths in m; panel sizes and NFA stay in inches because that is how products are sold.
- Alside, D5 Punched Soffit sell sheet: 12 ft fully vented or solid vinyl panels, 5.3 sq in of net free area per lineal foot (used as the default NFA)
- Mitten, Triple 4" vinyl soffit product page: 12 ft × 12 in panel, perforated full vent 5.89 sq in and lanced full vent 7.2 sq in of net free air intake per foot
- Kent, Double 5" Perforated Soffit product page: 4.2 sq in of net free air intake per foot (a lower, different hole pattern)
- Gibraltar Building Products, 16 in × 12 ft aluminum vented soffit, Home Depot listing: the aluminum panel size used here, listed at 6.48 sq in of net free area per lineal foot (Gibraltar’s help center gives 6.48 for its 16 in × 144 in vented soffit)
- Sell Even 16 in × 12 ft vented aluminum soffit, Menards listing: 6.48 sq in of net free air ventilation per lineal foot (one retailer listing; other makers differ)
- CertainTeed, Deluxe F-Channel (Amerhart listing): 12 ft 6 in length, receives soffit panels
- Mastic Vinyl F-Channel, 1/2 in × 12 ft 6 in (Super Arbor listing): vinyl channel in 12.5 ft lengths
- Amerimax White Aluminum J-Channel, 12 ft (Do it Best listing): the aluminum channel length used here
- Gibraltar Building Products, 24 in × 50 ft aluminum trim coil, Home Depot listing: the coil size used for fascia covering
- CertainTeed, Soffit Installation guide (Amerhart document): measure wall to fascia and subtract 1/2 in for expansion; nail channels about every 16 in; nailing strips where the eave span is over 16 in
- APA The Engineered Wood Association, Builder Tip N330, Panels for Soffit Applications: exterior panels for closed soffits
- International Residential Code (ICC), Section R806 Roof Ventilation, R806.2: net free ventilating area 1/150 of the vented space, 1/300 where the exception is met (the same rule as the attic ventilation calculator)
- Air Vent SV201 continuous aluminum soffit vent, 9 sq in of net free area per linear foot, as used by the attic ventilation calculator on this site
- Allowing about 2.5 in on top of the fascia face for coil wrap, and sourcing fascia boards in 12 ft or 16 ft lengths, are typical figures (estimates), not from a published standard
How to calculate soffit and fascia materials
- Measure the eaves and rakes. Add up the eave length. Add the rake length too only if you will box the rakes.
- Measure the overhang. Measure from the wall to the fascia. Note the height of the fascia face.
- Pick the material. Vinyl 12 in × 12 ft, aluminum 16 in × 12 ft or plywood 4 × 8 ft sheets. The calculator counts the pieces each panel gives at your overhang.
- Add the channel and fascia. Channel at the wall and the fascia, so twice the run, in 12 ft to 12.5 ft pieces; fascia coil or boards over the eave and rake length.
- Check the vent area. If the soffit is vented, enter the panel’s NFA per foot and the attic floor area to compare the intake with the attic ventilation rule.
Worked examples
| Project | Result |
|---|---|
| 40 × 30 ft gable house: 80 ft of eave at 16 in, 36 ft of boxed rake at 12 in, vinyl, 10% extra, aluminum coil fascia | 14 panels (143 sq ft of soffit), 21 lengths of channel, 2 coils of fascia coil |
| 100 ft of eave, no rakes, 12 in overhang, aluminum 16 in panels, 5% extra, 1 × 8 fascia boards in 16 ft lengths | 7 panels (100 sq ft of soffit), 18 lengths of channel, 7 fascia boards |
| 60 ft of eave, no rakes, 24 in overhang, plywood 4 × 8 ft sheets, solid soffit, 10% extra | 5 panels (120 sq ft of soffit), no channel, 1 coil of fascia coil |
Frequently asked questions
- How many soffit panels do I need?
- Work out how many pieces one panel gives, then divide. A 12 ft vinyl panel cut to a 16 in overhang gives 9 pieces, each 12 in wide, so it covers 9 ft of eave. 80 ft of eave and 36 ft of boxed rake (rake at a 12 in overhang, 12 ft per panel) is 80 ÷ 9 + 36 ÷ 12 = 11.9 panels; with 10% extra that is 14. The calculator does this for any overhang and material.
- What size are soffit panels?
- Vinyl soffit is commonly sold as 12 in wide panels 12 ft long (Triple 4 and Double 5 profiles), aluminum soffit as 16 in by 12 ft panels, and plywood as 4 × 8 ft sheets. Other widths and lengths exist, so check the panel you buy: the calculator assumes the nominal sizes.
- How much J-channel or F-channel do I need?
- Vinyl and aluminum soffit sits in a channel at the wall and another at the fascia, so you need the run length twice. F-channel, J-channel and similar receiving channel come in 12 ft (aluminum) and 12 ft 6 in (vinyl) lengths. The example with 116 ft of eave and rake needs 21 lengths with 10% extra. Plywood soffit needs no channel.
- How do I work out fascia coil or boards?
- Fascia length is the eave plus the rake. Aluminum trim coil comes in 24 in wide, 50 ft rolls and is cut into strips about 2.5 in wider than the fascia face, so a 6 in face gives 2 strips and a coil covers 100 ft. Boards are counted in 12 ft or 16 ft pieces. The calculator shows both ways.
- How much net free area does vented soffit have?
- It depends on the product: published figures run from about 4.2 to 7.2 sq in per lineal foot for vented vinyl (Alside D5 punched is 5.3), about 6.5 sq in per foot for one 16 in aluminum vented panel, and 9 sq in per foot for a continuous aluminum vent strip. Use the number printed on your panel; the NFA field takes it.
- Is the soffit venting enough for my attic?
- The calculator uses the same rule as the attic ventilation calculator: 1 sq ft of net free area per 150 sq ft of attic floor (1/300 where the code exception applies), split between intake at the eaves and exhaust high up. For a 1,200 sq ft attic at 1/150 and a 50/50 split that is 576 sq in of intake. 80 ft of all-vented panels at 5.3 sq in per ft supply 424 sq in, so you would add vented soffit elsewhere, use a higher-rated panel, or add other intake. With half the soffit vented it is 212 sq in. Code wording differs by edition, so confirm with your building department.
- Do rake soffits count as ventilation?
- No. A boxed rake closes the overhang along the gable end and does not open into the attic’s eave cavity, so only the eave soffit counts toward intake. The calculator counts rake soffit for panels and fascia only.
- Can I use plywood for soffit?
- Yes. APA says exterior panels should be used for a closed soffit, and a sanded or textured exterior face with paint holds up best. At a 24 in overhang the calculator gets 5 sheets for 60 ft of eave with 10% extra, because 4 × 8 sheets rip into 2 strips of 24 in. Plywood soffit has no vents of its own: cut vent openings or add vent strips if the attic needs intake.
- Does this count nails, nailing strips and lookouts?