Roof Pitch Calculator: Pitch, Angle, Slope and Roof Area

A roof that rises 6 in over a 12 in run is a 6:12 pitch, 26.57°, 50.0% slope, multiplier 1.118. On a 40 × 30 ft house with a 12 in overhang that is 42 × 32 = 1,344 sq ft of footprint, so the sloping surface is 1,503 sq ft (15 squares): the footprint times the multiplier 1.118. Pitch is the rise in inches for every 12 in of run, so 6:12 is also written 6/12 and spoken "six-twelve". Asphalt shingles need at least 2:12 under the IRC, with two layers of underlayment below 4:12.

Figures based on the sources listed belowUpdated How we calculate

Use whichever you measured. Rise and run is one measured stretch of the slope; rise and span is the height of the ridge over the full width of a symmetric gable.

How far the roof goes up over the run below, measured straight up. Any unit works if rise and run use the same one; inches are shown.

The level distance the rise happens over. A level held 12 in out from the roof, measured down to the roof, gives the rise for a 12 in run.

How far the roof sticks out past the walls, added on every side for the roof area. Use 0 if the length and width you entered already include it.

6:12 pitch, 26.57°, 50.0% slope, multiplier 1.118.

6:12 pitch, 26.57°, 50.0% slope, multiplier 1.118

  • Pitch (rise per 12 in of run): 6:12
  • Angle: 26.57°
  • Slope (rise ÷ run): 50.0%
  • Pitch multiplier (rafter length factor): 1.118, multiply a run by this for the length along the slope
  • Roof area (footprint with overhang × multiplier): 1,503 sq ft
  • Roofing squares (100 sq ft each): 15.0
  • Asphalt shingles (IRC R905.2.2): 4:12 or more, shingles with the normal single layer of underlayment
  • Metal panels and membranes (IRC R905): 3:12 or more, lapped exposed-fastener metal panels allowed without lap sealant

Shopping list

  • Digital angle finder or level
  • Speed square (rafter square)
  • Pitch gauge / roof slope finder
  • Tape measure, 25 ft
  • Laser distance measurer
  • Roof harness and rope grab kit
Show diagram

Saved projects

No saved projects yet.

Roof pitch table: 1:12 to 18:12

Worked by this calculator. Angle = atan(pitch ÷ 12), slope % = pitch ÷ 12 × 100, multiplier = √(1 + (pitch ÷ 12)²). Multiply a footprint area or a run by the multiplier for the sloping area or length. The last column is the code position for the common coverings, not a design check.
PitchAngleSlope %MultiplierRoofing note
1:124.76°8.3%1.003Low-slope roofing only
2:129.46°16.7%1.014Shingles with two layers of underlayment; lapped metal needs sealant
3:1214.04°25.0%1.031Shingles with two layers of underlayment
4:1218.43°33.3%1.054Single layer of shingle underlayment
5:1222.62°41.7%1.083Single layer of shingle underlayment
6:1226.57°50.0%1.118Single layer of shingle underlayment
7:1230.26°58.3%1.158Single layer of shingle underlayment
8:1233.69°66.7%1.202Single layer of shingle underlayment
9:1236.87°75.0%1.250Single layer of shingle underlayment
10:1239.81°83.3%1.302Single layer of shingle underlayment
11:1242.51°91.7%1.357Single layer of shingle underlayment
12:1245.00°100.0%1.414Single layer of shingle underlayment
13:1247.29°108.3%1.474Steep: fall protection and extra fastening
14:1249.40°116.7%1.537Steep: fall protection and extra fastening
15:1251.34°125.0%1.601Steep: fall protection and extra fastening
16:1253.13°133.3%1.667Steep: fall protection and extra fastening
17:1254.78°141.7%1.734Steep: fall protection and extra fastening
18:1256.31°150.0%1.803Steep: fall protection and extra fastening

Minimum roof slopes in the IRC

Slopes are rise per 12 in of run. Local amendments and the manufacturer may require more; check the edition your area adopted.
Roof coveringMinimum slopeNote
Asphalt shingles (R905.2.2)2:12 (17%)Two layers of underlayment from 2:12 up to under 4:12 (R905.1.1)
Lapped metal panels, no lap sealant (R905.10.2)3:12 (25%)Exposed-fastener panels with non-soldered seams
Lapped metal panels with lap sealant (R905.10.2)1/2:12 (4%)Sealant applied to the maker’s instructions
Standing-seam metal (R905.10.2)1/4:12 (2%)Check the panel maker for its own minimum
Built-up, modified bitumen and single-ply membrane (R905.9, R905.11, R905.12)1/4:12 (2%)Coal-tar built-up roofs 1/8:12 (1%); a design slope for drainage

Methodology & assumptions

Pick how you know the slope. With rise and run, the pitch is rise ÷ run × 12, the rise in inches per 12 in of run; any unit works if both use the same one. With rise and span, for a symmetric gable, the run is half the span, so the pitch is rise ÷ (span ÷ 2) × 12. With an angle, the pitch is 12 × tan(angle). From the pitch, the angle is atan(pitch ÷ 12), the slope percent is pitch ÷ 12 × 100, and the pitch multiplier (also called the rafter length factor, slope factor or pitch factor) is √(1 + (pitch ÷ 12)²), the length along the slope for each unit of run. The roof area is the footprint, with the overhang added on every side, times the multiplier. It holds for a gable or hip roof when every plane has the same pitch, and it is the same model as the roofing shingles calculator, so the two agree; skylight and chimney openings come off the sloping area. A square is 100 sq ft of roof. The pitch table is worked with the same formulas. The code minimums come from the International Residential Code: asphalt shingles on slopes of 2:12 or more (R905.2.2), with two layers of underlayment from 2:12 up to under 4:12 (R905.1.1), lapped exposed-fastener metal panels without lap sealant on 3:12 or more, with standing seam at 1/4:12 and lapped panels with lap sealant at 1/2:12 (R905.10.2), and built-up, modified bitumen and single-ply membrane roofs at 1/4:12 for drainage (R905.9, R905.11, R905.12). Section numbers and wording differ between code editions, local codes amend them, and a manufacturer's instructions can ask for more, so check your adopted code and the product's instructions. This calculator does not size rafters or judge whether a roof is safe to walk on.

How to find your roof pitch and roof area

  1. Measure the slope. Measure the rise over a known run (a level held out 12 in, or a vertical rise over half the span from the attic), or read the angle with a digital angle finder.
  2. Enter the slope. Pick rise and run, rise and span or angle, and type the measurements in the same unit.
  3. Read the pitch. The calculator gives the pitch as x:12, the angle, the slope percent and the pitch multiplier.
  4. Enter the footprint. Type the building length and width and the overhang. The roof area is the footprint with the overhang times the multiplier.
  5. Check the roofing rules. Compare the pitch with the minimum slopes for your roofing: 2:12 for shingles, 3:12 for lapped exposed-fastener metal, and your local code and the product instructions.

Worked examples

ProjectResult
40 × 30 ft house, 12 in overhang, 6 in rise over a 12 in run6:12 pitch, 26.57°, 50.0% slope, multiplier 1.118; 1,503 sq ft of roof (15 squares)
36 × 24 ft gable house, 12 in overhang, ridge 84 in above the eave line over a 288 in (24 ft) span7:12 pitch, 30.26°, 58.3% slope, multiplier 1.158; 1,144 sq ft of roof (11.4 squares)
32 × 22 ft house, 12 in overhang, roof angle read as 30 degrees6.93:12 pitch, 30.00°, 57.7% slope, multiplier 1.155; 942 sq ft of roof (9.4 squares)
28 × 16 ft garage, 12 in overhang, 3 in rise over a 12 in run, one 2 × 4 ft skylight3:12 pitch, 14.04°, 25.0% slope, multiplier 1.031; 549 sq ft of roof after the skylight (5.5 squares). 3:12: 2:12 to under 4:12, shingles allowed with two layers of underlayment; 3:12 or more, lapped exposed-fastener metal panels allowed without lap sealant

Frequently asked questions

How do I calculate roof pitch?
Divide the rise by the run and multiply by 12. A roof that rises 6 in over a 12 in run is 6:12. If you measured a different run, the same rule applies: 7:12 comes from an 84 in rise over a 144 in run (half of a 24 ft span). The calculator takes rise and run, rise and span or an angle and gives the pitch as x:12.
How do I measure roof pitch?
Hold a level horizontally against the roof, mark 12 in along it from the roof, and measure straight down from that mark to the roof; that reading is the rise per 12. From the attic, measure along a rafter instead: the vertical drop over a level 12 in is the same number. A digital angle finder laid on the roof gives the angle, which this calculator also accepts. Working on a roof needs fall protection; measure from a ladder or the attic where you can.
What is the pitch multiplier?
The pitch multiplier, also called the rafter length factor, slope factor or pitch factor, is √(1 + (pitch ÷ 12)²). Multiply a horizontal run by it to get the length along the slope, or a footprint by it to get the roof area. At 6:12 it is 1.118, at 12:12 it is 1.414. The table on this page lists 1:12 to 18:12.
How do I turn a pitch into degrees?
The angle is the arctangent of pitch ÷ 12. A 6:12 roof is 26.57°, 12:12 is exactly 45°, and a 4:12 roof is 18.43°. Going the other way, the pitch is 12 × tan(angle): 6.93:12 for 30°.
What is the slope percent of a 6:12 roof?
50.0%. Slope percent is rise ÷ run × 100, so 6 ÷ 12 is 50%. Percent is not the same as degrees: a 100% slope is 45°, not 100°. A 4:12 roof is 33.3%.
What is the minimum roof pitch for asphalt shingles?
The International Residential Code (R905.2.2) allows asphalt shingles on slopes of 2:12 (about 17%) or more. From 2:12 up to under 4:12 the code calls for two layers of underlayment instead of one (R905.1.1), and many shingle makers and roofers suggest 4:12 or more for good drainage. Below 2:12 use a low-slope roofing system. Section numbers and wording differ by edition, local codes amend them, and the shingle maker’s instructions can require more.
What is the minimum pitch for a metal roof?
In the IRC (R905.10.2), lapped, exposed-fastener metal panels without lap sealant need 3:12 (25%); with lap sealant applied to the maker’s instructions the minimum drops to 1/2:12; standing-seam systems are allowed at 1/4:12. Panel makers often set their own minimums, so check the product data sheet.
What is a low-slope roof?
Codes treat slopes below 2:12 as low-slope and need roofing made for it, such as built-up, modified bitumen or single-ply membrane roofs, which the IRC allows down to a design slope of 1/4:12 for drainage (1/8:12 for coal-tar built-up). Shingles are not allowed there.
How do I find the roof area from the pitch?
Add the overhang to the building length and width, multiply them for the footprint, and multiply by the pitch multiplier. The 40 × 30 ft example has a 12 in overhang, so 42 × 32 = 1,344 sq ft times 1.118 is 1,503 sq ft, or 15 squares. For shingle bundles use the roofing shingles calculator, which uses the same area.
What is considered a steep roof?
There is no single code line, but roofers commonly call anything over 7:12 steep and anything over 12:12 very steep. Walking and working on it needs harnesses and roof brackets, and shingle makers ask for extra fastening on steep slopes. That is an estimate of trade usage, not a code limit.