Sheets of rigid foam = area × layers × 1.10 ÷ the area of one sheet (32 sq ft for 4 × 8, 16 for 2 × 8), rounded up. A 30 × 8 ft wall is 240 sq ft, 264 sq ft with 10% waste: 9 sheets of 4 × 8 ft board (17 of 2 × 8), one layer of 2 in XPS for R-10 at R-5 per inch. To reach R-20 it takes two layers, 17 sheets. Total R is thickness × R per inch for each layer, added. Taping the outer layer takes about 90 ft of seam tape (1 roll), and cap nails on a stud wall about 240. The tape, nail and adhesive counts are typical estimates.

Figures based on the sources listed belowUpdated How we calculate

Waste allowance
Sets the fasteners: cap nails on stud walls, adhesive on basement walls, none under a slab. Seam tape is counted in all three.
R-value per inch is the same set of figures the wall R-value calculator uses. Polyiso loses R in cold weather and is usually not used below grade.
Thickness of one layer. Not every thickness is made in every foam type; check what your supplier stocks.
4 × 8 ft sheets have the fewest seams; 2 × 8 ft sheets are easier to carry and fit between wall studs or furring.

How many layers of this thickness to stack, with the joints staggered. Ignored when you enter a target R-value.

Leave empty to use the layers above. Enter an R-value (for example from your local energy code) to get the layers needed to reach it.

Buy 9 sheets.

Buy 9 sheets

240 sq ft + 10% waste = 264 sq ft

  • Total R-value: R-10 (1 layer of 2 in XPS)
  • Seam tape, outer layer (typical 180 ft rolls): 1 roll (≈ 90 ft)
  • Cap nails (typical, estimate): 240 nails

Low

$459.00

Expected

$612.00

High

$792.00

Includes 24 sq ft waste

How this number is calculated

240 sq ft + 10% waste = 264 sq ft ÷ 32 sq ft per sheet = 9 sheets

Next step in your project

Shopping list

  • Foam board cap nails
  • Foamboard construction adhesive
  • Foam board seam tape
  • Rigid foam board insulation, 4×8
  • Foam board cutting knife
  • Safety glasses
Show diagram

Saved projects

No saved projects yet.

R-value of one layer by thickness

Thickness × R per inch (EPS 4, XPS 5, polyiso 6). Nominal values at 75°F; stack layers to add them.
ThicknessEPSXPSPolyiso
0.5 inR-2R-2.5R-3
0.75 inR-3R-3.8R-4.5
1 inR-4R-5R-6
1.5 inR-6R-7.5R-9
2 inR-8R-10R-12
2.5 inR-10R-12.5R-15
3 inR-12R-15R-18
4 inR-16R-20R-24

Foam thickness needed for a target R-value

Total thickness in inches, all layers together, before rounding up to whole boards. Check your local energy code for the R-value you need.
TargetEPSXPSPolyiso
R-51.25 in1 in0.83 in
R-102.5 in2 in1.67 in
R-133.25 in2.6 in2.17 in
R-153.75 in3 in2.5 in
R-205 in4 in3.33 in
R-307.5 in6 in5 in

How much rigid foam for common jobs

Worked by this calculator: one layer, no openings subtracted, 10% waste, rounded up to whole sheets.
JobArea (sq ft)4 × 8 sheets2 × 8 sheetsR-value
Basement wall, 40 ft × 8 ft, 2 in XPS3201122R-10
Basement walls, 100 ft × 8 ft, 2 in EPS8002855R-8
Garage wall, 20 ft × 8 ft, 1.5 in polyiso160611R-9
House walls, 120 ft × 9 ft, 1 in XPS1,0803875R-5
Under a 24 × 30 ft slab, 2 in XPS7202550R-10
Under a 12 × 12 ft shop slab, 1 in EPS144510R-4

Methodology & assumptions

The area is length × width in feet (wall length × height, or slab length × width), minus any doors or windows you add. The layers are either the number you enter or, if you enter a target R-value, the target divided by the R-value of one layer (thickness × R per inch) rounded up. Sheets are area × layers × (1 + waste) ÷ the area of one sheet, 32 sq ft for 4 × 8 ft or 16 sq ft for 2 × 8 ft, rounded up; waste is 10%, or 15% for many cuts. R per inch uses the same figures as the wall R-value calculator: EPS 4, XPS 5 and polyiso 6. These are nominal values. Owens Corning FOAMULAR 150 and DuPont Styrofoam Square Edge XPS are both rated R-5 per inch at 75°F after aging, and Rmax Thermasheath-3 polyiso lists R-6.0 at 1 in, R-13.1 at 2 in and R-27.4 at 4 in at 75°F, so R-6 per inch is a little conservative for thick polyiso. Polyiso loses R-value in cold weather, so the polyiso figure is best for mild conditions, and most makers do not recommend it below grade; EPS and XPS are the usual choices there. Real products vary: EPS is commonly R-3.6 to R-4.2 per inch depending on density. Layers add: R-values in series sum, so two 2 in layers of XPS make R-20. Stagger the joints between layers. This counts the foam only; framing, cavity insulation, sheathing and air films are in the wall R-value calculator. Seam tape is the joints of the outer layer only, area × (1 ÷ sheet width + 1 ÷ sheet length) feet, which runs a little high because it also counts the outer edges, bought in rolls of 180 ft (a typical size). On a stud wall the cap nails are an estimate of 1 per sq ft of each layer, a 12 in grid; makers publish their own schedule (one foam sheathing guide asks for 12 in on center in the field and 6 in on the edges), so follow the guide for your product. On a basement wall the adhesive is an estimate of beads about 16 in apart (0.75 ft of bead per sq ft of each layer) at 32 ft of 1/4 in bead per 10.3 oz tube, a retail listing for DAP DynaGrip foamboard adhesive. Under a slab the board is laid loose with no fasteners. The adhesive and nail figures are typical estimates, not manufacturer coverage rates. Energy codes set minimum insulation by climate zone and many states amend them: this page does not reproduce the IECC table, so enter the figure from your local code as the target R-value. Lengths show in m under the metric toggle; sheet sizes and thicknesses stay in inches and feet as sold in the US.

How to calculate how much rigid foam insulation you need

  1. Pick where it goes. Choose a stud wall, a basement wall or under a slab. This sets whether you need cap nails, adhesive or neither.
  2. Enter the size. Enter the wall length and height, or the slab length and width, and add each door or window as an opening.
  3. Choose the foam and thickness. Pick EPS, XPS or polyiso and a board thickness. One layer is thickness × R per inch.
  4. Set the layers or a target R. Enter how many layers to stack, or a target R-value from your local energy code and let the calculator count the layers.
  5. Round up to whole sheets. Choose 4 × 8 or 2 × 8 ft sheets and the waste, then add seam tape and the nails or adhesive.

Worked examples

ProjectResult
30 × 8 ft wall, one layer of 2 in XPS (R-10)240 sq ft + 10% waste, R-10 (1 layer of 2 in XPS) → 9 sheets
Same wall, target R-20 (two layers)240 sq ft + 10% waste, R-20 (2 layers of 2 in XPS, target R-20) → 17 sheets
100 × 8 ft basement walls, 2 in EPS with adhesive, 2 × 8 sheets800 sq ft + 10% waste, R-8 (1 layer of 2 in EPS) → 55 sheets
24 × 30 ft slab, 2 in XPS under it720 sq ft + 10% waste, R-10 (1 layer of 2 in XPS) → 25 sheets

Frequently asked questions

How many sheets of rigid foam board do I need?
Find the area: wall length × height, or slab length × width, minus large openings. Multiply by the number of layers and by 1.10 for waste, then divide by the area of one sheet (32 sq ft for 4 × 8 ft, 16 sq ft for 2 × 8 ft) and round up. A 30 × 8 ft wall with one layer is 264 sq ft with waste, which is 9 sheets of 4 × 8 or 17 of 2 × 8.
What is the R-value of EPS, XPS and polyiso foam board?
This calculator uses R-4 per inch for EPS, R-5 for XPS and R-6 for polyiso, the same figures as the wall R-value calculator. Owens Corning and DuPont both rate their XPS at R-5 per inch. Rmax lists its Thermasheath-3 polyiso at R-6.0 for 1 in and R-13.1 for 2 in at 75°F. EPS varies with density, usually between about R-3.6 and R-4.2. Read the R-value printed on the board you buy.
How do I get to a target R-value with foam board?
Divide the target by the R-value of one layer and round up. One layer of 2 in XPS is R-10, so R-20 takes two layers: for the 30 × 8 ft wall, 17 sheets of 4 × 8. Enter a target in the calculator and it counts the layers for you. The result can overshoot the target, because layers are whole boards. Stagger the joints so a seam in one layer is covered by the board in the next.
What R-value does my climate zone require?
It depends on your climate zone, the edition of the energy code your state or city has adopted, and whether the foam is on a wall, a basement wall or under a slab. The model code is the IECC, Table R402.1.3, but many states amend it, so this page does not quote numbers. Look up the table your building department uses and enter the continuous insulation R-value as the target.
Do I need to tape the seams of foam board?
On an exterior wall the seams of the outer layer are usually taped with a tape the maker approves, to help with air and water sealing; not every tape sticks to XPS, so use one listed for your board. As an estimate that is area × (1 ÷ sheet width + 1 ÷ sheet length) feet. The 30 × 8 ft wall needs about 90 ft: 1 roll of 180 ft, a typical roll size.
How many cap nails or how much adhesive for foam board?
These are typical estimates, not manufacturer rates. On a stud wall the calculator counts about 1 cap nail per sq ft of each layer, a 12 in grid, which is 240 for the 30 × 8 ft wall. One foam sheathing guide asks for 12 in on center in the field and 6 in at the edges, so follow the schedule for your product. On a basement wall, foamboard adhesive in beads about 16 in apart comes to about 0.75 ft of bead per sq ft; at 32 ft per 10.3 oz tube, 100 × 8 ft of 2 in EPS is about 19 tubes. Under a slab the board is laid loose.
Which foam is best for a basement wall or under a slab?
EPS and XPS are the usual choices below grade because they tolerate moisture. Polyiso is generally not recommended below grade and loses R-value in cold weather, so the calculator flags it under a slab. Under a slab the board also has to carry the load: look at the compressive strength on the data sheet. Check the maker’s guide for the product you choose.
Should I use 4 × 8 or 2 × 8 sheets?
4 × 8 ft sheets have the fewest seams, so less tape and fewer places for air to leak. 2 × 8 ft sheets are easier to carry down basement stairs and fit between studs or furring. The 30 × 8 ft wall takes 9 sheets of 4 × 8 or 17 of 2 × 8, both for the same area.